Electrostatic gating in carbon nanotube aptasensors. Issue 28 (4th July 2016)
- Record Type:
- Journal Article
- Title:
- Electrostatic gating in carbon nanotube aptasensors. Issue 28 (4th July 2016)
- Main Title:
- Electrostatic gating in carbon nanotube aptasensors
- Authors:
- Zheng, Han Yue
Alsager, Omar A.
Zhu, Bicheng
Travas-Sejdic, Jadranka
Hodgkiss, Justin M.
Plank, Natalie O. V. - Abstract:
- Abstract : Synthetic DNA aptamer receptors could boost the prospects of carbon nanotube (CNT)-based electronic biosensors if signal transduction can be understood and engineered. Abstract : Synthetic DNA aptamer receptors could boost the prospects of carbon nanotube (CNT)-based electronic biosensors if signal transduction can be understood and engineered. Here, we report CNT aptasensors for potassium ions that clearly demonstrate aptamer-induced electrostatic gating of electronic conduction. The CNT network devices were fabricated on flexible substrates via a facile solution processing route and non-covalently functionalised with potassium binding aptamers. Monotonic increases in CNT conduction were observed in response to increasing potassium ion concentration, with a level of detection as low as 10 picomolar. The signal was shown to arise from a specific aptamer–target interaction that stabilises a G-quadruplex structure, bringing high negative charge density near the CNT channel. Electrostatic gating is established via the specificity and the sign of the current response, and by observing its suppression when higher ionic strength decreases the Debye length at the CNT–water interface. Sensitivity towards potassium and selectivity against other ions is demonstrated in both resistive mode and real time transistor mode measurements. The effective device architecture presented, along with the identification of clear response signatures, should inform the development of newAbstract : Synthetic DNA aptamer receptors could boost the prospects of carbon nanotube (CNT)-based electronic biosensors if signal transduction can be understood and engineered. Abstract : Synthetic DNA aptamer receptors could boost the prospects of carbon nanotube (CNT)-based electronic biosensors if signal transduction can be understood and engineered. Here, we report CNT aptasensors for potassium ions that clearly demonstrate aptamer-induced electrostatic gating of electronic conduction. The CNT network devices were fabricated on flexible substrates via a facile solution processing route and non-covalently functionalised with potassium binding aptamers. Monotonic increases in CNT conduction were observed in response to increasing potassium ion concentration, with a level of detection as low as 10 picomolar. The signal was shown to arise from a specific aptamer–target interaction that stabilises a G-quadruplex structure, bringing high negative charge density near the CNT channel. Electrostatic gating is established via the specificity and the sign of the current response, and by observing its suppression when higher ionic strength decreases the Debye length at the CNT–water interface. Sensitivity towards potassium and selectivity against other ions is demonstrated in both resistive mode and real time transistor mode measurements. The effective device architecture presented, along with the identification of clear response signatures, should inform the development of new electronic biosensors using the growing library of aptamer receptors. … (more)
- Is Part Of:
- Nanoscale. Volume 8:Issue 28(2016)
- Journal:
- Nanoscale
- Issue:
- Volume 8:Issue 28(2016)
- Issue Display:
- Volume 8, Issue 28 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 28
- Issue Sort Value:
- 2016-0008-0028-0000
- Page Start:
- 13659
- Page End:
- 13668
- Publication Date:
- 2016-07-04
- Subjects:
- Nanoscience -- Periodicals
Nanotechnology -- Periodicals
620.505 - Journal URLs:
- http://www.rsc.org/Publishing/Journals/NR/Index.asp ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c5nr08117c ↗
- Languages:
- English
- ISSNs:
- 2040-3364
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9830.266000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1418.xml