Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs. (30th May 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs. (30th May 2016)
- Main Title:
- Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs
- Authors:
- Garofalo, N.A.
Teixeira‐Neto, F.J.
Rodrigues, J.C.
Cerejo, S.A.
Aguiar, A.J.A.
Becerra‐Velásquez, D.R. - Abstract:
- Abstract : Background: Transpulmonary thermodilution (TPTDCO ) and calibrated pulse contour analysis (PCACO ) are alternatives to pulmonary artery thermodilution cardiac output (PATDCO ) measurement. Hypothesis: Ten mL of ice‐cold thermal indicator (TI10 ) would improve the agreement and trending ability between TPTDCO and PATDCO compared to 5 mL of indicator (TI5 ) (Phase‐1). The agreement and TA between PCACO and PATDCO would be poor during changes in systemic vascular resistance (SVR) (Phase‐2). Animals: Eight clinically normal dogs (20.8–31.5 kg). Methods: Prospective, experimental study. Simultaneous TPTDCO and PATDCO (averaged from 3 repetitions) using TI5 and TI10 were obtained during isoflurane anesthesia combined or not with remifentanil or dobutamine (Phase‐1). Triplicate PCACO and PATDCO measurements were recorded during phenylephrine‐induced vasoconstriction and nitroprusside‐induced vasodilation (Phase‐2). Results: Mean bias (limits of agreement: LOA) (L/min), percentage bias (PB), and percentage error (PE) were 0.62 (−0.11 to 1.35), 16%, and 19% for TI5 ; and 0.33 (−0.25 to 0.91), 9%, and 16% for TI10 . Mean bias (LOA), PB, and PE were 0.22 (−0.63 to 1.07), 6%, and 23% during phenylephrine; and 2.12 (0.70–3.55), 43%, and 29% during nitroprusside. Mean angular bias (radial LOA) values were 2° (−10° to 14°) and −1° (−9° to 6°) for TI5 and TI10, respectively (Phase‐1), and 38° (5°–71°) (Phase‐2). Conclusions and Clinical Importance: Although TI10 slightly improvesAbstract : Background: Transpulmonary thermodilution (TPTDCO ) and calibrated pulse contour analysis (PCACO ) are alternatives to pulmonary artery thermodilution cardiac output (PATDCO ) measurement. Hypothesis: Ten mL of ice‐cold thermal indicator (TI10 ) would improve the agreement and trending ability between TPTDCO and PATDCO compared to 5 mL of indicator (TI5 ) (Phase‐1). The agreement and TA between PCACO and PATDCO would be poor during changes in systemic vascular resistance (SVR) (Phase‐2). Animals: Eight clinically normal dogs (20.8–31.5 kg). Methods: Prospective, experimental study. Simultaneous TPTDCO and PATDCO (averaged from 3 repetitions) using TI5 and TI10 were obtained during isoflurane anesthesia combined or not with remifentanil or dobutamine (Phase‐1). Triplicate PCACO and PATDCO measurements were recorded during phenylephrine‐induced vasoconstriction and nitroprusside‐induced vasodilation (Phase‐2). Results: Mean bias (limits of agreement: LOA) (L/min), percentage bias (PB), and percentage error (PE) were 0.62 (−0.11 to 1.35), 16%, and 19% for TI5 ; and 0.33 (−0.25 to 0.91), 9%, and 16% for TI10 . Mean bias (LOA), PB, and PE were 0.22 (−0.63 to 1.07), 6%, and 23% during phenylephrine; and 2.12 (0.70–3.55), 43%, and 29% during nitroprusside. Mean angular bias (radial LOA) values were 2° (−10° to 14°) and −1° (−9° to 6°) for TI5 and TI10, respectively (Phase‐1), and 38° (5°–71°) (Phase‐2). Conclusions and Clinical Importance: Although TI10 slightly improves the agreement and trending ability between TPTDCO and PATDCO in comparison to TI5, both volumes can be used for TPTDCO in replacement of PATDCO . Vasodilation worsens the agreement between PCACO and PATDCO . Because of PCACO 's poor agreement and trending ability with PATDCO during SVR changes, this method has limited clinical application. … (more)
- Is Part Of:
- Journal of veterinary internal medicine. Volume 30:Number 4(2016:Jul./Aug.)
- Journal:
- Journal of veterinary internal medicine
- Issue:
- Volume 30:Number 4(2016:Jul./Aug.)
- Issue Display:
- Volume 30, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 4
- Issue Sort Value:
- 2016-0030-0004-0000
- Page Start:
- 941
- Page End:
- 950
- Publication Date:
- 2016-05-30
- Subjects:
- Indicator dilution cardiac output -- Monitoring -- Pulse contour analysis
Veterinary medicine -- Periodicals
636.0896 - Journal URLs:
- http://www.jvetintmed.org ↗
http://www3.interscience.wiley.com/journal/118902531/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jvim.13984 ↗
- Languages:
- English
- ISSNs:
- 0891-6640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5072.365000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1400.xml