Unexpected increase in indoor pollutants after the introduction of a smoke‐free policy in a correctional center. (10th August 2015)
- Record Type:
- Journal Article
- Title:
- Unexpected increase in indoor pollutants after the introduction of a smoke‐free policy in a correctional center. (10th August 2015)
- Main Title:
- Unexpected increase in indoor pollutants after the introduction of a smoke‐free policy in a correctional center
- Authors:
- He, C.
Knibbs, L. D.
Tran, Q.
Wang, H.
Laiman, R.
Wang, B.
Gu, Y.
Morawska, L. - Abstract:
- Abstract: Correctional centers (prisons) are one of the few non‐residential indoor environments where smoking is still permitted. However, few studies have investigated indoor air quality (IAQ) in these locations. We quantified the level of inmate and staff exposure to secondhand smoke, including particle number (PN) count, and we assessed the impact of the smoking ban on IAQ. We performed measurements of indoor and outdoor PM2.5 and PN concentrations, personal PN exposure levels, volatile organic compounds (VOCs), and nicotine both before and after a complete indoor smoking ban in an Australian maximum security prison. Results show that the indoor 24‐h average PM2.5 concentrations ranged from 6 (±1) μ g/m 3 to 17 (±3) μ g/m 3 pre‐ban. The post‐ban levels ranged from 7 (±2) μ g/m 3 to 71 (±43) μ g/m 3 . While PM2.5 concentrations decreased in one unit post‐ban, they increased in the other two units. Similar post‐ban increases were also observed in levels of PN and VOCs. We describe an unexpected increase of indoor pollutants following a total indoor smoking ban in a prison that was reflected across multiple pollutants that are markers of smoking. We hypothesise that clandestine post‐ban smoking among inmates may have been the predominant cause.
- Is Part Of:
- Indoor air. Volume 26:Number 4(2016:Aug.)
- Journal:
- Indoor air
- Issue:
- Volume 26:Number 4(2016:Aug.)
- Issue Display:
- Volume 26, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2016-0026-0004-0000
- Page Start:
- 623
- Page End:
- 633
- Publication Date:
- 2015-08-10
- Subjects:
- Indoor air -- Prison -- Jail -- Particle number -- PM 2.5 -- VOCs
Indoor air pollution -- Periodicals
Sick building syndrome -- Periodicals
Ventilation -- Periodicals
613.5 - Journal URLs:
- http://www.blackwell-synergy.com/loi/ina ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1600-0668 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/ina.12238 ↗
- Languages:
- English
- ISSNs:
- 0905-6947
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4438.046530
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1736.xml