Influence of different lubricants on the retentive force of LOCATOR® attachments – an in vitro pilot study. Issue 7 (9th September 2015)
- Record Type:
- Journal Article
- Title:
- Influence of different lubricants on the retentive force of LOCATOR® attachments – an in vitro pilot study. Issue 7 (9th September 2015)
- Main Title:
- Influence of different lubricants on the retentive force of LOCATOR® attachments – an in vitro pilot study
- Authors:
- Srinivasan, Murali
Schimmel, Martin
Kobayashi, Mariko
Badoud, Isabelle
Ammann, Patrick
Herrmann, François R.
Müller, Frauke - Abstract:
- Abstract: Objective: The aim of this in vitro pilot study was to evaluate the influence of an artificial saliva (AS) lubricant on the retentive force of a stud‐type attachment (LOCATOR ® ) for implant overdentures (IODs). Methods: Twenty custom‐made models simulating a two‐IOD with parallel implant situation were fabricated using LOCATOR ® attachments. The in vitro testing was carried out with an Instron ® universal testing machine for a total of 10, 000 insertion–removal cycles, for each model, in two different aqueous test mediums (Group 1: 0.9% sodium chloride solution (NaCl), n = 10; Group 2: AS, n = 10). Changes in the mean retentive force ( F ) were plotted against the cycle numbers #10, #100, #1000, #5000, and #10, 000. Mixed regression models were applied for statistical analyses. Results: A mixed regression (not considering interactions) predicted, compared to cycle #10, higher retentive forces at cycles #100 ( P < 0.0001), #1000 ( P = 0.017), similar forces at #5000 ( P = 0.277), and lower forces at #10, 000 ( P = 0.012); there was no overall effect of the medium ( P = 0.159). A second statistical model, employing the interaction term "cycle##medium", confirmed similarly the effect. Although the interaction term was significant at cycle #100 ( p = 0.045), there was no significant difference between the two groups ( P = 0.140). Conclusion: In this in vitro pilot experiment, there was no difference in mean retentive forces of the LOCATOR ®Abstract: Objective: The aim of this in vitro pilot study was to evaluate the influence of an artificial saliva (AS) lubricant on the retentive force of a stud‐type attachment (LOCATOR ® ) for implant overdentures (IODs). Methods: Twenty custom‐made models simulating a two‐IOD with parallel implant situation were fabricated using LOCATOR ® attachments. The in vitro testing was carried out with an Instron ® universal testing machine for a total of 10, 000 insertion–removal cycles, for each model, in two different aqueous test mediums (Group 1: 0.9% sodium chloride solution (NaCl), n = 10; Group 2: AS, n = 10). Changes in the mean retentive force ( F ) were plotted against the cycle numbers #10, #100, #1000, #5000, and #10, 000. Mixed regression models were applied for statistical analyses. Results: A mixed regression (not considering interactions) predicted, compared to cycle #10, higher retentive forces at cycles #100 ( P < 0.0001), #1000 ( P = 0.017), similar forces at #5000 ( P = 0.277), and lower forces at #10, 000 ( P = 0.012); there was no overall effect of the medium ( P = 0.159). A second statistical model, employing the interaction term "cycle##medium", confirmed similarly the effect. Although the interaction term was significant at cycle #100 ( p = 0.045), there was no significant difference between the two groups ( P = 0.140). Conclusion: In this in vitro pilot experiment, there was no difference in mean retentive forces of the LOCATOR ® attachments when tested with either 0.9% NaCl or a Glandosane ® ‐like artificial saliva lubricant. A larger scale study may still confirm the superiority of either lubricant for quasiclinical bench experiments. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 27:Issue 7(2016)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 27:Issue 7(2016)
- Issue Display:
- Volume 27, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 7
- Issue Sort Value:
- 2016-0027-0007-0000
- Page Start:
- 771
- Page End:
- 775
- Publication Date:
- 2015-09-09
- Subjects:
- artificial saliva -- dislodging cycles -- in vitro testing -- LOCATOR® attachments -- overdentures -- retentive force
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12680 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2712.xml