A screening and determinative method for the analysis of natural and synthetic steroids, stilbenes and resorcyclic acid lactones in bovine urine. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- A screening and determinative method for the analysis of natural and synthetic steroids, stilbenes and resorcyclic acid lactones in bovine urine. Issue 5 (May 2016)
- Main Title:
- A screening and determinative method for the analysis of natural and synthetic steroids, stilbenes and resorcyclic acid lactones in bovine urine
- Authors:
- Akre, Christine
Mizuno, Masahiro - Other Names:
- Boison Joe guestEditor.
Akre Christine guestEditor. - Abstract:
- Abstract : Our laboratory has four separate methods for the analysis of trenbolone, stilbenes, resorcyclic acid lactones, and estradiol in bovine urine. The method described in this paper was in response to a client request to consolidate the methods preferably into one method. A multiresidue semi‐quantitative method was developed and any suspect positive samples detected by the method were subjected to the method of standard addition to accurately quantify the concentration of the positive analyte. Samples were enzymatically hydrolyzed using β‐glucuronidase after which, supported liquid extraction on HM‐N cartridges was performed, followed by solvent exchange into methyl tert‐butyl ether (MTBE). The samples were evaporated and reconstituted into 10% methanol in water and loaded onto a SampliQ OPT SPE. The cleaned‐up extract was further cleaned up on a SampliQ NH2 cartridge. The SPE eluate was split into two for analysis by gas chromatography‐mass spectrometry (GC‐MS) using electron ionization (EI) and liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) using both positive and negative electrospray. It was found that with the exception of estradiol and trenbolone all compounds could be analyzed by both GC‐MS and LC‐MS/MS, providing a semi‐quantitative method. It is recommended that quantification is achieved using standard addition. Of the 13 compounds successfully monitored, the limits of detection (LODs), and the limits of quantification (LOQs) obtained were withinAbstract : Our laboratory has four separate methods for the analysis of trenbolone, stilbenes, resorcyclic acid lactones, and estradiol in bovine urine. The method described in this paper was in response to a client request to consolidate the methods preferably into one method. A multiresidue semi‐quantitative method was developed and any suspect positive samples detected by the method were subjected to the method of standard addition to accurately quantify the concentration of the positive analyte. Samples were enzymatically hydrolyzed using β‐glucuronidase after which, supported liquid extraction on HM‐N cartridges was performed, followed by solvent exchange into methyl tert‐butyl ether (MTBE). The samples were evaporated and reconstituted into 10% methanol in water and loaded onto a SampliQ OPT SPE. The cleaned‐up extract was further cleaned up on a SampliQ NH2 cartridge. The SPE eluate was split into two for analysis by gas chromatography‐mass spectrometry (GC‐MS) using electron ionization (EI) and liquid chromatography‐tandem mass spectrometry (LC‐MS/MS) using both positive and negative electrospray. It was found that with the exception of estradiol and trenbolone all compounds could be analyzed by both GC‐MS and LC‐MS/MS, providing a semi‐quantitative method. It is recommended that quantification is achieved using standard addition. Of the 13 compounds successfully monitored, the limits of detection (LODs), and the limits of quantification (LOQs) obtained were within the Codex limits for the target concentrations. As far as the authors are aware, the use of supported liquid extraction has not been reported for bovine urine analysis. © 2016 Her Majesty the Queen in Right of Canada. Drug Testing and Analysis © 2016 John Wiley & Sons, Ltd. Abstract : The validation of a determinative method for the analysis of natural and synthetic steroids, stilbenes and resorcyclic acid lactones in bovine urine is described. The method uses supported liquid extraction to remove aqueous interferences before SPE clean up. Quantification limits are below 2.5 ng/mL for all compounds. … (more)
- Is Part Of:
- Drug testing and analysis. Volume 8:Issue 5/6(2016:May)
- Journal:
- Drug testing and analysis
- Issue:
- Volume 8:Issue 5/6(2016:May)
- Issue Display:
- Volume 8, Issue 5/6 (2016)
- Year:
- 2016
- Volume:
- 8
- Issue:
- 5/6
- Issue Sort Value:
- 2016-0008-NaN-0000
- Page Start:
- 448
- Page End:
- 457
- Publication Date:
- 2016-05
- Subjects:
- bovine urine -- steroids -- stilbenes -- resorcyclic acid lactones -- mass spectrometry
Drugs -- Analysis -- Periodicals
Drug testing -- Periodicals
Chemistry, Forensic -- Periodicals
615.1901 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1942-7611 ↗
http://rzblx1.uni-regensburg.de/ezeit/warpto.phtml?colors=7&jour_id=110501 ↗
http://www3.interscience.wiley.com/journal/121408477/home ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/dta.2012 ↗
- Languages:
- English
- ISSNs:
- 1942-7603
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3629.424000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1987.xml