Development of a high‐throughput mass spectrometry based analytical method to support an in vitro OATP1B1 inhibition screening assay. (7th July 2016)
- Record Type:
- Journal Article
- Title:
- Development of a high‐throughput mass spectrometry based analytical method to support an in vitro OATP1B1 inhibition screening assay. (7th July 2016)
- Main Title:
- Development of a high‐throughput mass spectrometry based analytical method to support an in vitro OATP1B1 inhibition screening assay
- Authors:
- Wagner, Andrew D.
Elkin, Lisa
Mosure, Kathy
Gallagher, Lizbeth
Stavola, Lindsey K.
Soars, Matthew G.
Shou, Wilson - Abstract:
- Abstract : Rationale: It is well known that the organic anion transporting polypeptide 1B1 (OATP1B1) plays a major role in the hepatic uptake of a range of drugs. To this end, it is pivotal that the potential for new molecular entities (NMEs) to inhibit OATP1B1 activity be assessed during early drug discovery. The work reported herein describes the development of a high‐throughput analytical method to measure the clinically relevant probe substrate, pitavastatin, for the in vitro assessment of OATP1B1 inhibition. Methods: Development of an analytical method capable of very fast throughput was crucial for the success of this assay and was accomplished using a system which combines direct, on‐line solid‐phase extraction (SPE) with highly sensitive, label‐free tandem mass spectrometry (MS/MS)‐based detection. Mass spectrometry analysis of pitavastatin, along with the stable isotopically labeled internal standard d5‐pitavastatin, was conducted using positive electrospray ionization (ESI) in selected reaction monitoring (SRM) mode. Results: The on‐line SPE‐MS/MS platform demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness to existing methodologies while achieving analytical cycle times of 10.4 seconds per well. Sensitivity exceeded what was necessary for our assay conditions, with a determined lower limit of quantification (LLOQ) for pitavastatin of 10 pM (picomolar) in assay matrix. Furthermore, the potency of multiple reference compounds wasAbstract : Rationale: It is well known that the organic anion transporting polypeptide 1B1 (OATP1B1) plays a major role in the hepatic uptake of a range of drugs. To this end, it is pivotal that the potential for new molecular entities (NMEs) to inhibit OATP1B1 activity be assessed during early drug discovery. The work reported herein describes the development of a high‐throughput analytical method to measure the clinically relevant probe substrate, pitavastatin, for the in vitro assessment of OATP1B1 inhibition. Methods: Development of an analytical method capable of very fast throughput was crucial for the success of this assay and was accomplished using a system which combines direct, on‐line solid‐phase extraction (SPE) with highly sensitive, label‐free tandem mass spectrometry (MS/MS)‐based detection. Mass spectrometry analysis of pitavastatin, along with the stable isotopically labeled internal standard d5‐pitavastatin, was conducted using positive electrospray ionization (ESI) in selected reaction monitoring (SRM) mode. Results: The on‐line SPE‐MS/MS platform demonstrated similar sensitivity, selectivity, reproducibility, linearity and robustness to existing methodologies while achieving analytical cycle times of 10.4 seconds per well. Sensitivity exceeded what was necessary for our assay conditions, with a determined lower limit of quantification (LLOQ) for pitavastatin of 10 pM (picomolar) in assay matrix. Furthermore, the potency of multiple reference compounds was shown to be within 2‐fold of IC50 values generated from liquid chromatography (LC)/MS/MS‐based literature values. Conclusions: A very fast and robust analytical method was successfully developed for the measurement of the clinically relevant OATP1B1 substrate, pitavastatin. The successful development and implementation of this very important early liability screen has helped to facilitate judicious lead candidate progression and will ultimately help build a greater understanding of OATP1B1‐NME interactions, in general. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 30:Number 15(2016)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 30:Number 15(2016)
- Issue Display:
- Volume 30, Issue 15 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 15
- Issue Sort Value:
- 2016-0030-0015-0000
- Page Start:
- 1787
- Page End:
- 1796
- Publication Date:
- 2016-07-07
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7655 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2232.xml