Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol‐enhanced 4D flow MRI. Issue 2 (12th February 2016)
- Record Type:
- Journal Article
- Title:
- Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol‐enhanced 4D flow MRI. Issue 2 (12th February 2016)
- Main Title:
- Assessment of the precision and reproducibility of ventricular volume, function, and mass measurements with ferumoxytol‐enhanced 4D flow MRI
- Authors:
- Hanneman, Kate
Kino, Aya
Cheng, Joseph Y.
Alley, Marcus T.
Vasanawala, Shreyas S. - Abstract:
- Abstract : Purpose: To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time‐resolved (4D) flow MRI relative to cine steady‐state free precession (SSFP). Materials and Methods: With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol‐enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short‐axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland–Altman (BA) analysis, and intraclass correlation (ICC). Results: Significant positive correlations were found between 4D flow and SSFP for ventricular volumes ( r = 0.808–0.972, P < 0.001), ejection fraction (EF) ( r = 0.900–928, P < 0.001), and mass ( r = 0.884–0.934, P < 0.001). BA relative limits of agreement for both ventricles were between –52% to 34% for volumes, –29% to 27% for EF, and –41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED‐ES mass for either LV (F = 2.05, P = 0.159) orAbstract : Purpose: To compare the precision and interobserver agreement of ventricular volume, function, and mass quantification by 3D time‐resolved (4D) flow MRI relative to cine steady‐state free precession (SSFP). Materials and Methods: With Institutional Research Board approval, informed consent, and HIPAA compliance, 22 consecutive patients with congenital heart disease (CHD) (10 males, 6.4 ± 4.8 years) referred for 3T ferumoxytol‐enhanced cardiac MRI were prospectively recruited. Complete ventricular coverage with standard 2D short‐axis cine SSFP and whole chest coverage with axial 4D flow were obtained. Two blinded radiologists independently segmented images for left ventricular (LV) and right ventricular (RV) myocardium at end systole (ES) and end diastole (ED). Statistical analysis included linear regression, analysis of variance (ANOVA), Bland–Altman (BA) analysis, and intraclass correlation (ICC). Results: Significant positive correlations were found between 4D flow and SSFP for ventricular volumes ( r = 0.808–0.972, P < 0.001), ejection fraction (EF) ( r = 0.900–928, P < 0.001), and mass ( r = 0.884–0.934, P < 0.001). BA relative limits of agreement for both ventricles were between –52% to 34% for volumes, –29% to 27% for EF, and –41% to 48% for mass, with wider limits of agreement for the RV compared to the LV. There was no significant difference between techniques with respect to mean square difference of ED‐ES mass for either LV (F = 2.05, P = 0.159) or RV (F = 0.625, P = 0.434). Interobserver agreement was moderate to good with both 4D flow (ICC 0.523–0.993) and SSFP (ICC 0.619–0.982), with overlapping confidence intervals. Conclusion: Quantification of ventricular volume, function, and mass can be accomplished with 4D flow MRI with precision and interobserver agreement comparable to that of cine SSFP. J. Magn. Reson. Imaging 2016;44:383–392. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 2(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 2(2016)
- Issue Display:
- Volume 44, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2016-0044-0002-0000
- Page Start:
- 383
- Page End:
- 392
- Publication Date:
- 2016-02-12
- Subjects:
- magnetic resonance imaging -- ventricular myocardium -- ventricular function -- 4D flow
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25180 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1993.xml