Diffusion tensor imaging of the human kidney: Does image registration permit scanning without respiratory triggering?. Issue 2 (12th February 2016)
- Record Type:
- Journal Article
- Title:
- Diffusion tensor imaging of the human kidney: Does image registration permit scanning without respiratory triggering?. Issue 2 (12th February 2016)
- Main Title:
- Diffusion tensor imaging of the human kidney: Does image registration permit scanning without respiratory triggering?
- Authors:
- Seif, Maryam
Mani, Laila Yasmin
Lu, Huanxiang
Boesch, Chris
Reyes, Mauricio
Vogt, Bruno
Vermathen, Peter - Abstract:
- Abstract : Purpose: To investigate if image registration of diffusion tensor imaging (DTI) allows omitting respiratory triggering for both transplanted and native kidneys Materials and Methods: Nine kidney transplant recipients and eight healthy volunteers underwent renal DTI on a 3T scanner with and without respiratory triggering. DTI images were registered using a multimodal nonrigid registration algorithm. Apparent diffusion coefficient (ADC), the contribution of perfusion (FP ), and the fractional anisotropy (FA) were determined. Relative root mean square errors (RMSE) of the fitting and the standard deviations of the derived parameters within the regions of interest (SDROI ) were evaluated as quality criteria. Results: Registration significantly reduced RMSE in all DTI‐derived parameters of triggered and nontriggered measurements in cortex and medulla of both transplanted and native kidneys ( P < 0.05 for all). In addition, SDROI values were lower with registration for all 16 parameters in transplanted kidneys (14 of 16 SDROI values were significantly reduced, P < 0.04) and for 15 of 16 parameters in native kidneys (9 of 16 SDROI values were significantly reduced, P < 0.05). Comparing triggered versus nontriggered DTI in transplanted kidneys revealed no significant difference for RMSE ( P > 0.14) and for SDROI ( P > 0.13) of all parameters. In contrast, in native kidneys relative RMSE from triggered scans were significantly lower than those from nontriggered scans ( P <Abstract : Purpose: To investigate if image registration of diffusion tensor imaging (DTI) allows omitting respiratory triggering for both transplanted and native kidneys Materials and Methods: Nine kidney transplant recipients and eight healthy volunteers underwent renal DTI on a 3T scanner with and without respiratory triggering. DTI images were registered using a multimodal nonrigid registration algorithm. Apparent diffusion coefficient (ADC), the contribution of perfusion (FP ), and the fractional anisotropy (FA) were determined. Relative root mean square errors (RMSE) of the fitting and the standard deviations of the derived parameters within the regions of interest (SDROI ) were evaluated as quality criteria. Results: Registration significantly reduced RMSE in all DTI‐derived parameters of triggered and nontriggered measurements in cortex and medulla of both transplanted and native kidneys ( P < 0.05 for all). In addition, SDROI values were lower with registration for all 16 parameters in transplanted kidneys (14 of 16 SDROI values were significantly reduced, P < 0.04) and for 15 of 16 parameters in native kidneys (9 of 16 SDROI values were significantly reduced, P < 0.05). Comparing triggered versus nontriggered DTI in transplanted kidneys revealed no significant difference for RMSE ( P > 0.14) and for SDROI ( P > 0.13) of all parameters. In contrast, in native kidneys relative RMSE from triggered scans were significantly lower than those from nontriggered scans ( P < 0.02), while SDROI was slightly higher in triggered compared to nontriggered measurements in 15 out of 16 comparisons (significantly for two, P < 0.05). Conclusion: Registration improves the quality of DTI in native and transplanted kidneys. Diffusion parameters in renal allografts can be measured without respiratory triggering. In native kidneys, respiratory triggering appears advantageous. J. Magn. Reson. Imaging 2016;44:327–334. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 2(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 2(2016)
- Issue Display:
- Volume 44, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 2
- Issue Sort Value:
- 2016-0044-0002-0000
- Page Start:
- 327
- Page End:
- 334
- Publication Date:
- 2016-02-12
- Subjects:
- DTI -- kidney -- motion correction -- diffusion -- respiratory triggering -- nonrigid image registration
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25176 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1993.xml