Discrimination of skin sensitizers from non‐sensitizers by interleukin‐1α and interleukin‐6 production on cultured human keratinocytes. Issue 9 (22nd December 2015)
- Record Type:
- Journal Article
- Title:
- Discrimination of skin sensitizers from non‐sensitizers by interleukin‐1α and interleukin‐6 production on cultured human keratinocytes. Issue 9 (22nd December 2015)
- Main Title:
- Discrimination of skin sensitizers from non‐sensitizers by interleukin‐1α and interleukin‐6 production on cultured human keratinocytes
- Authors:
- Jung, Daun
Che, Jeong‐Hwan
Lim, Kyung‐Min
Chun, Young‐Jin
Heo, Yong
Seok, Seung Hyeok - Abstract:
- Abstract: In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as the murine local lymph node assay (LLNA) and the guinea pig maximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non‐sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. HaCaT cells were exposed to 16 relevant skin sensitizers and 6 skin non‐sensitizers. The highest dose used was the dose causing 75% cell viability (CV75) that we determined by an MTT [3‐(4, 5‐dimethylthiazol‐2‐yl)‐2, 5‐diphenyltetrazolium bromide] assay. The levels of extracellular production of interleukin‐1α (IL‐1α) and IL‐6 were measured. The sensitivity of IL‐1α was 63%, specificity was 83% and accuracy was 68%. In the case of IL‐6, sensitivity: 69%, specificity: 83% and accuracy: 73%. Thus, this study suggests that measuring extracellular production of pro‐inflammatory cytokines IL‐1α and IL‐6 by human HaCaT cells may potentially classify skin sensitizers from non‐sensitizers. Copyright © 2015 John Wiley & Sons, Ltd. Abstract : In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as themurine local lymph node assay (LLNA) and the guinea pigmaximizationAbstract: In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as the murine local lymph node assay (LLNA) and the guinea pig maximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non‐sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. HaCaT cells were exposed to 16 relevant skin sensitizers and 6 skin non‐sensitizers. The highest dose used was the dose causing 75% cell viability (CV75) that we determined by an MTT [3‐(4, 5‐dimethylthiazol‐2‐yl)‐2, 5‐diphenyltetrazolium bromide] assay. The levels of extracellular production of interleukin‐1α (IL‐1α) and IL‐6 were measured. The sensitivity of IL‐1α was 63%, specificity was 83% and accuracy was 68%. In the case of IL‐6, sensitivity: 69%, specificity: 83% and accuracy: 73%. Thus, this study suggests that measuring extracellular production of pro‐inflammatory cytokines IL‐1α and IL‐6 by human HaCaT cells may potentially classify skin sensitizers from non‐sensitizers. Copyright © 2015 John Wiley & Sons, Ltd. Abstract : In vitro testing methods for classifying sensitizers could be valuable alternatives to in vivo sensitization testing using animal models, such as themurine local lymph node assay (LLNA) and the guinea pigmaximization test (GMT), but there remains a need for in vitro methods that are more accurate and simpler to distinguish skin sensitizers from non‐sensitizers. Thus, the aim of our study was to establish an in vitro assay as a screening tool for detecting skin sensitizers using the human keratinocyte cell line, HaCaT. … (more)
- Is Part Of:
- Journal of applied toxicology. Volume 36:Issue 9(2016)
- Journal:
- Journal of applied toxicology
- Issue:
- Volume 36:Issue 9(2016)
- Issue Display:
- Volume 36, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 36
- Issue:
- 9
- Issue Sort Value:
- 2016-0036-0009-0000
- Page Start:
- 1129
- Page End:
- 1136
- Publication Date:
- 2015-12-22
- Subjects:
- cultured human keratinocyte -- HaCaT -- interleukin‐1α -- interleukin‐6 -- skin sensitizer
Toxicology -- Periodicals
Industrial toxicology -- Periodicals
Environmentally induced diseases -- Periodicals
Toxicology -- Periodicals
615.9005 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1099-1263/issues ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jat.3274 ↗
- Languages:
- English
- ISSNs:
- 0260-437X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4947.130000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 685.xml