Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy. Issue 7 (July 2016)
- Record Type:
- Journal Article
- Title:
- Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy. Issue 7 (July 2016)
- Main Title:
- Translational and rotational localization errors in cone-beam CT based image-guided lung stereotactic radiotherapy
- Authors:
- Garibaldi, Cristina
Piperno, Gaia
Ferrari, Annamaria
Surgo, Alessia
Muto, Matteo
Ronchi, Sara
Bazani, Alessia
Pansini, Floriana
Cremonesi, Marta
Jereczek-Fossa, Barbara Alicja
Orecchia, Roberto - Abstract:
- Highlights: We determined localization and residual errors for 57 lung SBRT using CBCT. Translational and rotational errors were detected using ITV/CBCT matching technique. The automatic 6D correction with the robotic couch increased localization accuracy. 5 mm safety margin to the ITV resulted adequate using the automatic 6D correction. Abstract: Purpose: Accurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins. Materials and methods: The internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors. Results: The mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SIHighlights: We determined localization and residual errors for 57 lung SBRT using CBCT. Translational and rotational errors were detected using ITV/CBCT matching technique. The automatic 6D correction with the robotic couch increased localization accuracy. 5 mm safety margin to the ITV resulted adequate using the automatic 6D correction. Abstract: Purpose: Accurate localization is crucial in delivering safe and effective stereotactic body radiation therapy (SBRT). The aim of this study was to analyse the accuracy of image-guidance using the cone-beam computed tomography (CBCT) of the VERO system in 57 patients treated for lung SBRT and to calculate the treatment margins. Materials and methods: The internal target volume (ITV) was obtained by contouring the tumor on maximum and mean intensity projection CT images reconstructed from a respiration correlated 4D-CT. Translational and rotational tumor localization errors were identified by comparing the manual registration of the ITV to the motion-blurred tumor on the CBCT and they were corrected by means of the robotic couch and the ring rotation. A verification CBCT was acquired after correction in order to evaluate residual errors. Results: The mean 3D vector at initial set-up was 6.6 ± 2.3 mm, which was significantly reduced to 1.6 ± 0.8 mm after 6D automatic correction. 94% of the rotational errors were within 3°. The PTV margins used to compensate for residual tumor localization errors were 3.1, 3.5 and 3.3 mm in the LR, SI and AP directions, respectively. Conclusions: On-line image guidance with the ITV–CBCT matching technique and automatic 6D correction of the VERO system allowed a very accurate tumor localization in lung SBRT. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 7(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 7(2016)
- Issue Display:
- Volume 32, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2016-0032-0007-0000
- Page Start:
- 859
- Page End:
- 865
- Publication Date:
- 2016-07
- Subjects:
- Translational and rotational localization error -- Lung SBRT -- Image-guided radiotherapy
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.05.055 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 517.xml