Pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of X-ray CT scanners. Issue 7 (July 2016)
- Record Type:
- Journal Article
- Title:
- Pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of X-ray CT scanners. Issue 7 (July 2016)
- Main Title:
- Pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of X-ray CT scanners
- Authors:
- Haba, Tomonobu
Koyama, Shuji
Aoyama, Takahiko
Kinomura, Yutaka
Ida, Yoshihiro
Kobayashi, Masanao
Kameyama, Hiroshi
Tsutsumi, Yoshinori - Abstract:
- Highlights: We devised a pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of CT scanners. The pin-photodiode array consisted of eight channels of X-ray sensors. Fan-beam energy could be measured with the rotating exposure mode of CT scanners. Abstract: Purpose: Patient dose estimation in X-ray computed tomography (CT) is generally performed by Monte Carlo simulation of photon interactions within anthropomorphic or cylindrical phantoms. An accurate Monte Carlo simulation requires an understanding of the effects of the bow-tie filter equipped in a CT scanner, i.e. the change of X-ray energy and air kerma along the fan-beam arc of the CT scanner. To measure the effective energy and air kerma distributions, we devised a pin-photodiode array utilizing eight channels of X-ray sensors arranged at regular intervals along the fan-beam arc of the CT scanner. Methods: Each X-ray sensor consisted of two plate type of pin silicon photodiodes in tandem – front and rear photodiodes – and of a lead collimator, which only allowed X-rays to impinge vertically to the silicon surface of the photodiodes. The effective energy of the X-rays was calculated from the ratio of the output voltages of the photodiodes and the dose was calculated from the output voltage of the front photodiode using the energy and dose calibration curves respectively. Results: The pin-photodiode array allowed the calculation of X-ray effective energies and relative doses, at eightHighlights: We devised a pin-photodiode array for the measurement of fan-beam energy and air kerma distributions of CT scanners. The pin-photodiode array consisted of eight channels of X-ray sensors. Fan-beam energy could be measured with the rotating exposure mode of CT scanners. Abstract: Purpose: Patient dose estimation in X-ray computed tomography (CT) is generally performed by Monte Carlo simulation of photon interactions within anthropomorphic or cylindrical phantoms. An accurate Monte Carlo simulation requires an understanding of the effects of the bow-tie filter equipped in a CT scanner, i.e. the change of X-ray energy and air kerma along the fan-beam arc of the CT scanner. To measure the effective energy and air kerma distributions, we devised a pin-photodiode array utilizing eight channels of X-ray sensors arranged at regular intervals along the fan-beam arc of the CT scanner. Methods: Each X-ray sensor consisted of two plate type of pin silicon photodiodes in tandem – front and rear photodiodes – and of a lead collimator, which only allowed X-rays to impinge vertically to the silicon surface of the photodiodes. The effective energy of the X-rays was calculated from the ratio of the output voltages of the photodiodes and the dose was calculated from the output voltage of the front photodiode using the energy and dose calibration curves respectively. Results: The pin-photodiode array allowed the calculation of X-ray effective energies and relative doses, at eight points simultaneously along the fan-beam arc of a CT scanner during a single rotation of the scanner. Conclusions: The fan-beam energy and air kerma distributions of CT scanners can be effectively measured using this pin-photodiode array. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 7(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 7(2016)
- Issue Display:
- Volume 32, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 7
- Issue Sort Value:
- 2016-0032-0007-0000
- Page Start:
- 905
- Page End:
- 913
- Publication Date:
- 2016-07
- Subjects:
- X-ray CT -- Fan-beam energy -- Pin-photodiode X-ray sensor
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.06.010 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 517.xml