Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure. (2nd June 2016)
- Record Type:
- Journal Article
- Title:
- Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure. (2nd June 2016)
- Main Title:
- Evaluation of wireless stimulation of the endocardium, WiSE, technology for treatment heart failure
- Authors:
- Seifert, M.
Butter, C. - Abstract:
- ABSTRACT: Introduction : There are several unsolved limitations in delivering cardiac resynchronization therapy. 30-40% of patients fail to have any clinical benefit after 6 months caused by different reasons. Areas covered : Endocardial stimulation rather than conventional epicardial pacing has been shown to: be more physiologically, improve electrical stimulation of the left ventricular, give less dispersion of repolarisation and result in better resynchronization. The Wireless Cardiac Stimulation in Left Ventricle, WiCS-LV, system provides an option for wireless, left ventricular endocardial pacing triggered from a conventional right ventricular pacing spike from a co-implant. Expert commentary : The feasibility of the WiCS-LV system has been successfully demonstrated in a population of failed cardiac resynchronization patients, either failed implantation procedure of a conventional system, non-responder to conventional therapy or upgrade from pacemaker or defibrillator, where a conventional system was not an option. WiCS-LV is innovative technology with promising safety, performance and preliminary efficacy.
- Is Part Of:
- Expert review of medical devices. Volume 13:Number 6(2016)
- Journal:
- Expert review of medical devices
- Issue:
- Volume 13:Number 6(2016)
- Issue Display:
- Volume 13, Issue 6 (2016)
- Year:
- 2016
- Volume:
- 13
- Issue:
- 6
- Issue Sort Value:
- 2016-0013-0006-0000
- Page Start:
- 523
- Page End:
- 531
- Publication Date:
- 2016-06-02
- Subjects:
- Cardiac resynchronization therapy implantation -- leadless left ventricular endocardial pacing -- heart failure -- ultrasound energy transfer
Medical instruments and apparatus -- Periodicals
610.28 - Journal URLs:
- http://informahealthcare.com/loi/erd ↗
http://www.future-drugs.com/loi/erd ↗
http://informahealthcare.com ↗ - DOI:
- 10.1080/17434440.2016.1187559 ↗
- Languages:
- English
- ISSNs:
- 1743-4440
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3842.002986
British Library DSC - BLDSS-3PM
British Library HMNTS - Digital store
British Library HMNTS - ELD Digital store - Ingest File:
- 1943.xml