The Plasmair Decontamination System Is Protective Against Invasive Aspergillosis in Neutropenic Patients. (8th April 2016)
- Record Type:
- Journal Article
- Title:
- The Plasmair Decontamination System Is Protective Against Invasive Aspergillosis in Neutropenic Patients. (8th April 2016)
- Main Title:
- The Plasmair Decontamination System Is Protective Against Invasive Aspergillosis in Neutropenic Patients
- Authors:
- Fernandez-Gerlinger, Marie-Paule
Jannot, Anne-Sophie
Rigaudeau, Sophie
Lambert, Juliette
Eloy, Odile
Mignon, François
Farhat, Hassan
Castaigne, Sylvie
Merrer, Jacques
Rousselot, Philippe - Abstract:
- Abstract : OBJECTIVE: Invasive aspergillosis (IA) is a rare but severe infection caused by Aspergillus spp. that often develops in immunocompromised patients. Lethality remains high in this population. Therefore, preventive strategies are of key importance. The impact of a mobile air decontamination system (Plasmair, AirInSpace, Montigny-le-Bretonneux, France) on the incidence of IA in neutropenic patients was evaluated in this study. DESIGN: Retrospective cohort study METHODS: Patients with chemotherapy-induced neutropenia lasting 7 days or more were included over a 2-year period. Cases of IA were confirmed using the revised European Organization for Research and Treatment of Cancer (EORTC) criteria. We took advantage of a partial installation of Plasmair systems in the hematology intensive care unit during this period to compare patients treated in Plasmair-equipped versus non-equipped rooms. Patients were assigned to Plasmair-equipped or non-equipped rooms depending only on bed availability. Differences in IA incidence in both groups were compared using Fisher's exact test, and a multivariate analysis was performed to take into account potential confounding factors. RESULTS: Data from 156 evaluable patients were available. Both groups were homogenous in terms of age, gender, hematological diagnosis, duration of neutropenia, and prophylaxis. A total of 11 cases of probable IA were diagnosed: 10 in patients in non-equipped rooms and only 1 patient in a Plasmair-equippedAbstract : OBJECTIVE: Invasive aspergillosis (IA) is a rare but severe infection caused by Aspergillus spp. that often develops in immunocompromised patients. Lethality remains high in this population. Therefore, preventive strategies are of key importance. The impact of a mobile air decontamination system (Plasmair, AirInSpace, Montigny-le-Bretonneux, France) on the incidence of IA in neutropenic patients was evaluated in this study. DESIGN: Retrospective cohort study METHODS: Patients with chemotherapy-induced neutropenia lasting 7 days or more were included over a 2-year period. Cases of IA were confirmed using the revised European Organization for Research and Treatment of Cancer (EORTC) criteria. We took advantage of a partial installation of Plasmair systems in the hematology intensive care unit during this period to compare patients treated in Plasmair-equipped versus non-equipped rooms. Patients were assigned to Plasmair-equipped or non-equipped rooms depending only on bed availability. Differences in IA incidence in both groups were compared using Fisher's exact test, and a multivariate analysis was performed to take into account potential confounding factors. RESULTS: Data from 156 evaluable patients were available. Both groups were homogenous in terms of age, gender, hematological diagnosis, duration of neutropenia, and prophylaxis. A total of 11 cases of probable IA were diagnosed: 10 in patients in non-equipped rooms and only 1 patient in a Plasmair-equipped room. The odds of developing IA were much lower for patients hospitalized in Plasmair-equipped rooms than for patients in non-equipped rooms (P=.02; odds ratio [OR] =0.11; 95% confidence interval [CI], 0.00–0.84). CONCLUSION: In this study, Plasmair demonstrated a major impact in reducing the incidence of IA in neutropenic patients with hematologic malignancies. Infect Control Hosp Epidemiol 2016;37:845–851 … (more)
- Is Part Of:
- Infection control and hospital epidemiology. Volume 37:Number 7(2016)
- Journal:
- Infection control and hospital epidemiology
- Issue:
- Volume 37:Number 7(2016)
- Issue Display:
- Volume 37, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2016-0037-0007-0000
- Page Start:
- 845
- Page End:
- 851
- Publication Date:
- 2016-04-08
- Subjects:
- Nosocomial infections -- Epidemiology -- Periodicals
Health facilities -- Sanitation -- Periodicals
Hospital buildings -- Sanitation -- Periodicals
Cross Infection -- Periodicals
Epidemiology -- Periodicals
Hospitals -- Periodicals
Infection Control -- Periodicals
614.44 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00004848-000000000-00000 ↗
http://journals.cambridge.org/action/displayJournal?jid=ICE ↗
http://www.ichejournal.com/default.asp ↗
http://www.journals.uchicago.edu/ICHE/home.html ↗
http://www.jstor.org/journals/0899823X.html ↗ - DOI:
- 10.1017/ice.2016.81 ↗
- Languages:
- English
- ISSNs:
- 0899-823X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library STI - ELD Digital store
- Ingest File:
- 649.xml