Reliability of single aliquot regenerative protocol (SAR) for dose estimation in quartz at different burial temperatures: A simulation study. (August 2016)
- Record Type:
- Journal Article
- Title:
- Reliability of single aliquot regenerative protocol (SAR) for dose estimation in quartz at different burial temperatures: A simulation study. (August 2016)
- Main Title:
- Reliability of single aliquot regenerative protocol (SAR) for dose estimation in quartz at different burial temperatures: A simulation study
- Authors:
- Koul, D.K.
Pagonis, V.
Patil, P. - Abstract:
- Abstract: The single aliquot regenerative protocol (SAR) is a well-established technique for estimating naturally acquired radiation doses in quartz. This simulation work examines the reliability of SAR protocol for samples which experienced different ambient temperatures in nature in the range of −10 to 40 °C. The contribution of various experimental variables used in SAR protocols to the accuracy and precision of the method is simulated for different ambient temperatures. Specifically the effects of paleo-dose, test dose, pre-heating temperature and cut-heat temperature on the accuracy of equivalent dose (ED) estimation are simulated by using random combinations of the concentrations of traps and centers using a previously published comprehensive quartz model. The findings suggest that the ambient temperature has a significant bearing on the reliability of natural dose estimation using SAR protocol, especially for ambient temperatures above 0 °C. The main source of these inaccuracies seems to be thermal sensitization of the quartz samples caused by the well-known thermal transfer of holes between luminescence centers in quartz. The simulations suggest that most of this inaccuracy in the dose estimation can be removed by delivering the laboratory doses in pulses (pulsed irradiation procedures). Highlights: Ambient temperatures affect the reliability of SAR. It overestimates the dose with increase in burial temperature and burial time periods. Elevated temperatureAbstract: The single aliquot regenerative protocol (SAR) is a well-established technique for estimating naturally acquired radiation doses in quartz. This simulation work examines the reliability of SAR protocol for samples which experienced different ambient temperatures in nature in the range of −10 to 40 °C. The contribution of various experimental variables used in SAR protocols to the accuracy and precision of the method is simulated for different ambient temperatures. Specifically the effects of paleo-dose, test dose, pre-heating temperature and cut-heat temperature on the accuracy of equivalent dose (ED) estimation are simulated by using random combinations of the concentrations of traps and centers using a previously published comprehensive quartz model. The findings suggest that the ambient temperature has a significant bearing on the reliability of natural dose estimation using SAR protocol, especially for ambient temperatures above 0 °C. The main source of these inaccuracies seems to be thermal sensitization of the quartz samples caused by the well-known thermal transfer of holes between luminescence centers in quartz. The simulations suggest that most of this inaccuracy in the dose estimation can be removed by delivering the laboratory doses in pulses (pulsed irradiation procedures). Highlights: Ambient temperatures affect the reliability of SAR. It overestimates the dose with increase in burial temperature and burial time periods. Elevated temperature irradiation does not correct for these overestimations. Inaccuracies in dose estimation can be removed by incorporating pulsed irradiation procedures. … (more)
- Is Part Of:
- Radiation measurements. Volume 91(2016:Aug.)
- Journal:
- Radiation measurements
- Issue:
- Volume 91(2016:Aug.)
- Issue Display:
- Volume 91 (2016)
- Year:
- 2016
- Volume:
- 91
- Issue Sort Value:
- 2016-0091-0000-0000
- Page Start:
- 28
- Page End:
- 35
- Publication Date:
- 2016-08
- Subjects:
- Luminescence -- Quartz model -- SAR protocol -- Pulsed irradiation
Nuclear emulsions -- Periodicals
Particle tracks (Nuclear physics) -- Periodicals
Thermoluminescence -- Periodicals
Cosmic rays -- Periodicals
Radiation -- Measurement -- Periodicals
Radiometry -- Periodicals
Radiation Monitoring -- Periodicals
Émulsions nucléaires -- Périodiques
Particules (Physique nucléaire) -- Traces -- Périodiques
Thermoluminescence -- Périodiques
Rayonnement cosmique -- Périodiques
Radiométrie -- Périodiques
539.77 - Journal URLs:
- http://www.sciencedirect.com/science/journal/13504487 ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiation-measurements/ ↗ - DOI:
- 10.1016/j.radmeas.2016.04.002 ↗
- Languages:
- English
- ISSNs:
- 1350-4487
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7227.973000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 600.xml