Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry. (August 2016)
- Record Type:
- Journal Article
- Title:
- Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry. (August 2016)
- Main Title:
- Measurement of clavicular length and shortening after a midshaft clavicular fracture: Spatial digitization versus planar roentgen photogrammetry
- Authors:
- Stegeman, Sylvia A.
de Witte, Pieter Bas
Boonstra, Sjoerd
de Groot, Jurriaan H.
Nagels, Jochem
Krijnen, Pieta
Schipper, Inger B. - Abstract:
- Abstract: Purpose : Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2 weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Patients and methods : Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland–Altman plot. Results : The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC > 0.90), but moderate for absolute shortening after consolidation (ICC = 0.45). The Bland–Altman plot compared measurements ofAbstract: Purpose : Clavicular shortening after fracture is deemed prognostic for clinical outcome and is therefore generally assessed on radiographs. It is used for clinical decision making regarding operative or non-operative treatment in the first 2 weeks after trauma, although the reliability and accuracy of the measurements are unclear. This study aimed to assess the reliability of roentgen photogrammetry (2D) of clavicular length and shortening, and to compare these with 3D-spatial digitization measurements, obtained with an electromagnetic recording system (Flock of Birds). Patients and methods : Thirty-two participants with a consolidated non-operatively treated two or multi-fragmented dislocated midshaft clavicular fracture were analysed. Two observers measured clavicular lengths and absolute and proportional clavicular shortening on radiographs taken before and after fracture consolidation. The clavicular lengths were also measured with spatial digitization. Inter-observer agreement on the radiographic measurements was assessed using the Intraclass Correlation Coefficient (ICC). Agreement between the radiographic and spatial digitization measurements was assessed using a Bland–Altman plot. Results : The inter-observer agreement on clavicular length, and absolute and proportional shortening on trauma radiographs was almost perfect (ICC > 0.90), but moderate for absolute shortening after consolidation (ICC = 0.45). The Bland–Altman plot compared measurements of length on AP panorama radiographs with spatial digitization and showed that planar roentgen photogrammetry resulted in up to 37 mm longer and 34 mm shorter measurements than spatial digitization. Conclusion : Measurements of clavicular length on radiographs are highly reliable between observers, but may not reflect the actual length and shortening of the clavicle when compared to length measurements with spatial digitization. We recommend to use proportional shortening when measuring clavicular length or shortening on radiographs for clinical decision making. … (more)
- Is Part Of:
- Journal of electromyography and kinesiology. Volume 29(2016:Aug.)
- Journal:
- Journal of electromyography and kinesiology
- Issue:
- Volume 29(2016:Aug.)
- Issue Display:
- Volume 29 (2016)
- Year:
- 2016
- Volume:
- 29
- Issue Sort Value:
- 2016-0029-0000-0000
- Page Start:
- 74
- Page End:
- 80
- Publication Date:
- 2016-08
- Subjects:
- Clavicle -- Fractures -- Shortening -- Radiography -- Diagnostic techniques and procedures -- Adult -- Observational study -- Fracture healing
Electromyography -- Periodicals
Kinesiology -- Periodicals
Electromyography -- Periodicals
Movement -- physiology -- Periodicals
Muscles -- physiology -- Periodicals
Électromyographie -- Périodiques
Cinésiologie -- Périodiques
Electromyography
Kinesiology
Electronic journals
Periodicals
616.740757 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10506411 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10506411 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jelekin.2015.07.007 ↗
- Languages:
- English
- ISSNs:
- 1050-6411
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4974.855000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 70.xml