On the prediction of shear brittle collapse mechanisms due to the infill-frame interaction in RC buildings under pushover analysis. (15th August 2016)
- Record Type:
- Journal Article
- Title:
- On the prediction of shear brittle collapse mechanisms due to the infill-frame interaction in RC buildings under pushover analysis. (15th August 2016)
- Main Title:
- On the prediction of shear brittle collapse mechanisms due to the infill-frame interaction in RC buildings under pushover analysis
- Authors:
- Fiore, Alessandra
Spagnoletti, Girolamo
Greco, Rita - Abstract:
- Highlights: The infill panel-frame interaction is investigated within pushover analyses. The "double-strut model" is adopted to simulate the infill behavior. The activation of local brittle collapse mechanisms is studied. The goal is to provide a practical tool for the prediction of shear demand. Dangerous shear failures compromising the structural safety can be detected. Abstract: A large number of research studies deal with the modeling and analysis of infilled reinforced concrete (RC) buildings under seismic actions, at the aim to understand the actual contribution given by masonry infills to the overall seismic resistance of a building. In this paper this aspect is investigated in the framework of pushover analyses, describing the theoretical and computational choices related to the involved parameters. Differently from the approaches available in literature and standards, the "double-strut model" is adopted to simulate the infill behavior, according to which an infill panel is represented by two equivalent non-parallel struts; the peculiarity is that the positions of the extremities of the two struts coincide with the points of application of the stress resultants on each side of the panel. The results show that, by adopting the double-strut model, it is possible to capture dangerous local shear failures which are usually neglected in pushover analysis and which can compromise the safety of the overall structure. By including in the analysis shear plastic hingesHighlights: The infill panel-frame interaction is investigated within pushover analyses. The "double-strut model" is adopted to simulate the infill behavior. The activation of local brittle collapse mechanisms is studied. The goal is to provide a practical tool for the prediction of shear demand. Dangerous shear failures compromising the structural safety can be detected. Abstract: A large number of research studies deal with the modeling and analysis of infilled reinforced concrete (RC) buildings under seismic actions, at the aim to understand the actual contribution given by masonry infills to the overall seismic resistance of a building. In this paper this aspect is investigated in the framework of pushover analyses, describing the theoretical and computational choices related to the involved parameters. Differently from the approaches available in literature and standards, the "double-strut model" is adopted to simulate the infill behavior, according to which an infill panel is represented by two equivalent non-parallel struts; the peculiarity is that the positions of the extremities of the two struts coincide with the points of application of the stress resultants on each side of the panel. The results show that, by adopting the double-strut model, it is possible to capture dangerous local shear failures which are usually neglected in pushover analysis and which can compromise the safety of the overall structure. By including in the analysis shear plastic hinges together with bending ones, it is evident how the additional shear forces, arising at the extremities of beams and columns, can substantially change the collapse mechanism of a structure under seismic action. The main features of the double-strut model are its low computational cost together with its accuracy, which make it particularly suitable for applications in the engineering practice. In fact it could be easily implemented in commercial calculation codes, representing a practical predictive tool able to enhance the safety level of infilled RC buildings. … (more)
- Is Part Of:
- Engineering structures. Volume 121(2016:Aug. 15)
- Journal:
- Engineering structures
- Issue:
- Volume 121(2016:Aug. 15)
- Issue Display:
- Volume 121 (2016)
- Year:
- 2016
- Volume:
- 121
- Issue Sort Value:
- 2016-0121-0000-0000
- Page Start:
- 147
- Page End:
- 159
- Publication Date:
- 2016-08-15
- Subjects:
- Reinforced concrete structure -- Infilled frame -- Double-strut model -- Shear brittle failure -- Collapse mechanism -- Pushover analysis
Structural engineering -- Periodicals
Structural analysis (Engineering) -- Periodicals
Construction, Technique de la -- Périodiques
Génie parasismique -- Périodiques
Pression du vent -- Périodiques
Earthquake engineering
Structural engineering
Wind-pressure
Periodicals
624.105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01410296 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.engstruct.2016.04.044 ↗
- Languages:
- English
- ISSNs:
- 0141-0296
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3770.032000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 869.xml