Clinical utility of testing AQP4-IgG in CSF: Guidance for physicians. Issue 3 (June 2016)
- Record Type:
- Journal Article
- Title:
- Clinical utility of testing AQP4-IgG in CSF: Guidance for physicians. Issue 3 (June 2016)
- Main Title:
- Clinical utility of testing AQP4-IgG in CSF
- Authors:
- Majed, Masoud
Fryer, James P.
McKeon, Andrew
Lennon, Vanda A.
Pittock, Sean J. - Abstract:
- Abstract : Objective: To define, using assays of optimized sensitivity and specificity, the most informative specimen type for aquaporin-4 immunoglobulin G (AQP4-IgG) detection. Methods: Results were reviewed from longitudinal service testing for AQP4-IgG among specimens submitted to the Mayo Clinic Neuroimmunology Laboratory from 101, 065 individual patients. Paired samples of serum/CSF were tested from 616 patients, using M1-AQP4-transfected cell-based assays (both fixed AQP4-CBA Euroimmun kit [commercial CBA] and live in-house flow cytometry [FACS]). Sensitivities were compared for 58 time-matched paired specimens (drawn ⩽30 days apart) from patients with neuromyelitis optica (NMO) or high-risk patients. Results: The frequency of CSF submission as sole initial specimen was 1 in 50 in 2007 and 1 in 5 in 2015. In no case among 616 paired specimens was CSF positive and serum negative. In 58 time-matched paired specimens, AQP4-IgG was detected by FACS or by commercial CBA more sensitively in serum than in CSF (respectively, p = 0.06 and p < 0.001). A serum titer >1:100 predicted CSF positivity ( p < 0.001). The probability of CSF positivity was greater around attack time ( p = 0.03). No control specimen from 128 neurologic patients was positive by either assay. Conclusions: FACS and commercial CBA detection of AQP4-IgG is less sensitive in CSF than in serum. The data suggest that most AQP4-IgG is produced in peripheral lymphoid tissues and that a critical serum/CSF gradientAbstract : Objective: To define, using assays of optimized sensitivity and specificity, the most informative specimen type for aquaporin-4 immunoglobulin G (AQP4-IgG) detection. Methods: Results were reviewed from longitudinal service testing for AQP4-IgG among specimens submitted to the Mayo Clinic Neuroimmunology Laboratory from 101, 065 individual patients. Paired samples of serum/CSF were tested from 616 patients, using M1-AQP4-transfected cell-based assays (both fixed AQP4-CBA Euroimmun kit [commercial CBA] and live in-house flow cytometry [FACS]). Sensitivities were compared for 58 time-matched paired specimens (drawn ⩽30 days apart) from patients with neuromyelitis optica (NMO) or high-risk patients. Results: The frequency of CSF submission as sole initial specimen was 1 in 50 in 2007 and 1 in 5 in 2015. In no case among 616 paired specimens was CSF positive and serum negative. In 58 time-matched paired specimens, AQP4-IgG was detected by FACS or by commercial CBA more sensitively in serum than in CSF (respectively, p = 0.06 and p < 0.001). A serum titer >1:100 predicted CSF positivity ( p < 0.001). The probability of CSF positivity was greater around attack time ( p = 0.03). No control specimen from 128 neurologic patients was positive by either assay. Conclusions: FACS and commercial CBA detection of AQP4-IgG is less sensitive in CSF than in serum. The data suggest that most AQP4-IgG is produced in peripheral lymphoid tissues and that a critical serum/CSF gradient is required for IgG to penetrate the CNS in pathogenic quantity. Serum is the optimal and most cost-effective specimen for AQP4-IgG testing. Classification of evidence: This study provides Class IV evidence that for patients with NMO or NMOSD, CSF is less sensitive than serum for detection of AQP4-IgG. … (more)
- Is Part Of:
- Neurology. Volume 3:Issue 3(2016)
- Journal:
- Neurology
- Issue:
- Volume 3:Issue 3(2016)
- Issue Display:
- Volume 3, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 3
- Issue:
- 3
- Issue Sort Value:
- 2016-0003-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06
- Subjects:
- Neuroimmunology -- Periodicals
Neurology -- Periodicals
616.8 - Journal URLs:
- http://nn.neurology.org/ ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.1212/NXI.0000000000000231 ↗
- Languages:
- English
- ISSNs:
- 2332-7812
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6081.502260
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1589.xml