Comparison of pulmonary arterial wall properties between a congenital heart disease patient and a normal subject using in vivo pressure–diameter measurements: A feasibility study. (June 2016)
- Record Type:
- Journal Article
- Title:
- Comparison of pulmonary arterial wall properties between a congenital heart disease patient and a normal subject using in vivo pressure–diameter measurements: A feasibility study. (June 2016)
- Main Title:
- Comparison of pulmonary arterial wall properties between a congenital heart disease patient and a normal subject using in vivo pressure–diameter measurements: A feasibility study
- Authors:
- Banerjee, Rajit
D'Souza, Gavin A.
Lee, Namheon
Taylor, Michael D. - Abstract:
- Abstract: Patients with congenital heart disease (CHD) requiring pulmonary valve and right ventricular intervention often suffer from residual lesions including pulmonary regurgitation or pulmonary artery (PA) obstruction after the placement of a patch or artificial conduit during surgery. These residual lesions can result in significant changes in the structure and function of the right ventricle (RV) and PA. Characterization of the material properties such as stress, strain, and compliance of the PA provides a quantitative assessment of RV–PA dysfunction and may aid in the longitudinal assessment of CHD patients. Thus, in this feasibility study, we aim to assess the variations in the material properties between the left PA (LPA) of a CHD patient, which was located in close proximity of the RV-main PA (MPA) homograft, and that of a normal subject (control) with a native LPA, using in vivo pressure–diameter data as input to a non-linear material model. In vivo LPA pressure and diameter were obtained using cardiac catheterization and cardiac MRI, respectively. This in vivo data was used in conjunction with a set of sample constitutive equations to define a 2D nonlinear anisotropic material model for the LPA. Subsequently, the model constants were predicted using an optimization algorithm and by applying an equilibrium condition to the LPA wall. The model was then used to predict the pressure–diameter and stress–stretch characteristics of the LPA of the patient and control.Abstract: Patients with congenital heart disease (CHD) requiring pulmonary valve and right ventricular intervention often suffer from residual lesions including pulmonary regurgitation or pulmonary artery (PA) obstruction after the placement of a patch or artificial conduit during surgery. These residual lesions can result in significant changes in the structure and function of the right ventricle (RV) and PA. Characterization of the material properties such as stress, strain, and compliance of the PA provides a quantitative assessment of RV–PA dysfunction and may aid in the longitudinal assessment of CHD patients. Thus, in this feasibility study, we aim to assess the variations in the material properties between the left PA (LPA) of a CHD patient, which was located in close proximity of the RV-main PA (MPA) homograft, and that of a normal subject (control) with a native LPA, using in vivo pressure–diameter data as input to a non-linear material model. In vivo LPA pressure and diameter were obtained using cardiac catheterization and cardiac MRI, respectively. This in vivo data was used in conjunction with a set of sample constitutive equations to define a 2D nonlinear anisotropic material model for the LPA. Subsequently, the model constants were predicted using an optimization algorithm and by applying an equilibrium condition to the LPA wall. The model was then used to predict the pressure–diameter and stress–stretch characteristics of the LPA of the patient and control. Based on the pressure–diameter curve predicted by the model, a greater slope was observed for the patient compared to the control, thus indicating a reduction in compliance of the patient's LPA due to the presence of a RV-MPA homograft. The stress–stretch characteristics indicated a higher stress for the patient's LPA compared to that of the control. Further, a difference between the circumferential and axial stresses confirmed the anisotropic nature of the artery. Thus, this feasibility study indicates that differences between a native and diseased PA can be evaluated using a material model in conjunction with in vivo pressure–diameter data. The material properties may provide insight into RV–PA dysfunction in post-operative CHD patients. Highlights: The material properties of a normal and abnormal pulmonary artery were evaluated. The pressure and diameter were obtained by catheterization and cardiac MRI. A non-linear anisotropic model was used to predict the material properties. Pressure–diameter characteristics showed lower compliance in the patient artery. The method can provide pulmonary artery properties as input for CFD models. … (more)
- Is Part Of:
- Progress in pediatric cardiology. Volume 41(2016)
- Journal:
- Progress in pediatric cardiology
- Issue:
- Volume 41(2016)
- Issue Display:
- Volume 41, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 41
- Issue:
- 2016
- Issue Sort Value:
- 2016-0041-2016-0000
- Page Start:
- 97
- Page End:
- 102
- Publication Date:
- 2016-06
- Subjects:
- Congenital heart disease -- Cardiac magnetic resonance -- Material model -- Pulmonary artery -- Material properties
Pediatric cardiology -- Periodicals
Cardiovascular Diseases -- Periodicals
Infant
Child
Cardiologie pédiatrique -- Périodiques
618.9212005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10589813 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10589813 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/10589813 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ppedcard.2015.12.007 ↗
- Languages:
- English
- ISSNs:
- 1058-9813
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6872.440000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 713.xml