Value of tomosynthesis for lesion evaluation of small joints in osteoarthritic hands using the OARSI score. Issue 7 (July 2016)
- Record Type:
- Journal Article
- Title:
- Value of tomosynthesis for lesion evaluation of small joints in osteoarthritic hands using the OARSI score. Issue 7 (July 2016)
- Main Title:
- Value of tomosynthesis for lesion evaluation of small joints in osteoarthritic hands using the OARSI score
- Authors:
- Martini, K.
Becker, A.S.
Guggenberger, R.
Andreisek, G.
Frauenfelder, T. - Abstract:
- Summary: Objective: To determine the diagnostic performance of tomosynthesis in depicting osteoarthritic lesions in comparison to conventional radiographs, with use of computed tomography (CT) as standard-of-reference. Methods: Imaging of 12 cadaveric hands was performed with tomosynthesis in dorso-palmar (dp) projection, conventional radiographs (dp) and multi-detector CT. Distal interphalangeal joint (DIP)II, DIPIII, proximal interphalangeal joint (PIP)II, PIPIII, first carpometacarpal (CMC) and scaphotrapezotrapezoidal joint (STT) were graded by two independent readers using the Osteoarthritis Research Society International (OARSI) score. The mean score for each feature was calculated for all modalities. Additional wrists were evaluated for presence of calcium pyrophosphate disease (CPPD). CT served as reference-standard. Inter-reader agreement (ICC) was calculated. Results: Comparing tomosynthesis and conventional radiographs to CT, the sensitivity for the presence of osteophytes was 95, 7% vs 65, 2%; for joint space narrowing 95, 8% vs 52, 1%; for subchondral sclerosis 61, 5% vs 51, 3%; for lateral deformity 83.3% vs 83, 3%; and for subchondral cysts 45, 8% vs 29, 2%. Erosions were not present. While tomosynthesis showed no significant difference in OARSI score grading to CT (mean OARSI-score CT: 16.8, SD = 10.6; mean OARSI-score Tomosynthesis: 16.3, SD = 9.6; P = 0.84), conventional radiographs had significant lower mean OARSI scores (mean OARSI-score X-ray: 11.1,Summary: Objective: To determine the diagnostic performance of tomosynthesis in depicting osteoarthritic lesions in comparison to conventional radiographs, with use of computed tomography (CT) as standard-of-reference. Methods: Imaging of 12 cadaveric hands was performed with tomosynthesis in dorso-palmar (dp) projection, conventional radiographs (dp) and multi-detector CT. Distal interphalangeal joint (DIP)II, DIPIII, proximal interphalangeal joint (PIP)II, PIPIII, first carpometacarpal (CMC) and scaphotrapezotrapezoidal joint (STT) were graded by two independent readers using the Osteoarthritis Research Society International (OARSI) score. The mean score for each feature was calculated for all modalities. Additional wrists were evaluated for presence of calcium pyrophosphate disease (CPPD). CT served as reference-standard. Inter-reader agreement (ICC) was calculated. Results: Comparing tomosynthesis and conventional radiographs to CT, the sensitivity for the presence of osteophytes was 95, 7% vs 65, 2%; for joint space narrowing 95, 8% vs 52, 1%; for subchondral sclerosis 61, 5% vs 51, 3%; for lateral deformity 83.3% vs 83, 3%; and for subchondral cysts 45, 8% vs 29, 2%. Erosions were not present. While tomosynthesis showed no significant difference in OARSI score grading to CT (mean OARSI-score CT: 16.8, SD = 10.6; mean OARSI-score Tomosynthesis: 16.3, SD = 9.6; P = 0.84), conventional radiographs had significant lower mean OARSI scores (mean OARSI-score X-ray: 11.1, SD = 8.3; P = 0.04). Inter-reader agreement for OARSI scoring was excellent (ICC = 0.99). CPPD calcifications present in CT, were also visible with tomosynthesis, but not with conventional radiography. Conclusion: In conclusion, tomosynthesis depicts more osteoarthritic changes in the small joints of the hand than conventional radiography using the OARSI scoring system and CT as the standard of reference. … (more)
- Is Part Of:
- Osteoarthritis and cartilage. Volume 24:Issue 7(2016)
- Journal:
- Osteoarthritis and cartilage
- Issue:
- Volume 24:Issue 7(2016)
- Issue Display:
- Volume 24, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 24
- Issue:
- 7
- Issue Sort Value:
- 2016-0024-0007-0000
- Page Start:
- 1167
- Page End:
- 1171
- Publication Date:
- 2016-07
- Subjects:
- Tomosynthesis -- Osteoarthritis -- Computed tomography -- Early detection -- Small joints
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Osteoarthritis -- Periodicals
Cartilage -- Periodicals
Arthrose -- Périodiques
Articulations -- Maladies -- Périodiques
616.7223005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/10634584 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/10634584 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.joca.2016.01.982 ↗
- Languages:
- English
- ISSNs:
- 1063-4584
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6303.858870
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: