A moot point! A homicide case report on ambiguous projectile movement on postmortem MR. (June 2016)
- Record Type:
- Journal Article
- Title:
- A moot point! A homicide case report on ambiguous projectile movement on postmortem MR. (June 2016)
- Main Title:
- A moot point! A homicide case report on ambiguous projectile movement on postmortem MR
- Authors:
- Gascho, Dominic
Ampanozi, Garyfalia
Ebert, Lars C
Bolliger, Stephan A
Eggert, Sebastian
Franckenberg, Sabine
Thali, Michael J
Flach, Patricia M - Abstract:
- Abstract: In a case of homicide with a lodged ricochet projectile in the skull, potential projectile movement was investigated by postmortem magnetic resonance imaging (PMMR). The purpose of this case report is to evaluate the different PMMR-related properties of projectiles in gunshot wounds. The deceased underwent whole-body postmortem computed tomography (PMCT) in a supine position, 3D-suface scanning with reposition of the corpse into a prone position and subsequent PMMR in the same position. For validation purposes, a control PMCT-scan in supine position followed by autopsy was also performed. The ferromagnetic properties of the projectile were tested. Imaging revealed projectile movement between PMCT and PMMR. The bullet did not produce excessive susceptibility artifacts on PMMR. Autopsy revealed no heating effects of the adjacent tissue, indicating no thermal effects by the PMMR scan. The bullet showed no ferromagnetic properties. Ballistic analysis showed only copper and lead compounds in the 9 mm projectile. Therefore, the bullet migration was caused by repositioning of the corpse from a supine to a prone position along the ricochet wound channel, not by magnetic torque during the PMMR scan. PMMR allows for better anatomical detail of the bullet path within soft tissue and may be performed in cases involving the vast majority of projectiles. Knowledge about potential ferromagnetic properties may have clinical implications for imaging in surviving patients ofAbstract: In a case of homicide with a lodged ricochet projectile in the skull, potential projectile movement was investigated by postmortem magnetic resonance imaging (PMMR). The purpose of this case report is to evaluate the different PMMR-related properties of projectiles in gunshot wounds. The deceased underwent whole-body postmortem computed tomography (PMCT) in a supine position, 3D-suface scanning with reposition of the corpse into a prone position and subsequent PMMR in the same position. For validation purposes, a control PMCT-scan in supine position followed by autopsy was also performed. The ferromagnetic properties of the projectile were tested. Imaging revealed projectile movement between PMCT and PMMR. The bullet did not produce excessive susceptibility artifacts on PMMR. Autopsy revealed no heating effects of the adjacent tissue, indicating no thermal effects by the PMMR scan. The bullet showed no ferromagnetic properties. Ballistic analysis showed only copper and lead compounds in the 9 mm projectile. Therefore, the bullet migration was caused by repositioning of the corpse from a supine to a prone position along the ricochet wound channel, not by magnetic torque during the PMMR scan. PMMR allows for better anatomical detail of the bullet path within soft tissue and may be performed in cases involving the vast majority of projectiles. Knowledge about potential ferromagnetic properties may have clinical implications for imaging in surviving patients of shootings. This case report shows that bullet migration may occur independently of magnetic torque and that the localization of the bullet during postmortem imaging and autopsy may have been altered in a ricochet shot. Graphical abstract: Highlights: Bullet migration may occur independently of magnetic torque. Most projectiles are not ferromagnetic. Non-ferromagnetic bullets produce scarce artifacts on PMMR. PMMR allows for more detailed soft tissue depiction than does PMCT. … (more)
- Is Part Of:
- Journal of forensic radiology and imaging. Volume 5(2016)
- Journal:
- Journal of forensic radiology and imaging
- Issue:
- Volume 5(2016)
- Issue Display:
- Volume 5, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 5
- Issue:
- 2016
- Issue Sort Value:
- 2016-0005-2016-0000
- Page Start:
- 62
- Page End:
- 67
- Publication Date:
- 2016-06
- Subjects:
- Virtopsy -- Projectile -- PMMR -- Virtual autopsy -- Postmortem magnetic resonance imaging -- Migration
Forensic radiography -- Periodicals
Magnetic resonance imaging -- Periodicals
Diagnostic imaging -- Periodicals
Diagnostic imaging
Forensic radiography
Magnetic resonance imaging
Periodicals
614.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/22124780 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.jofri.2015.08.004 ↗
- Languages:
- English
- ISSNs:
- 2212-4780
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1540.xml