Reinforced fixation of distal fibula fractures in elderly patients; A meta-analysis of biomechanical studies. (July 2016)
- Record Type:
- Journal Article
- Title:
- Reinforced fixation of distal fibula fractures in elderly patients; A meta-analysis of biomechanical studies. (July 2016)
- Main Title:
- Reinforced fixation of distal fibula fractures in elderly patients; A meta-analysis of biomechanical studies
- Authors:
- Dingemans, Siem A.
Lodeizen, Olivia A.P.
Goslings, J. Carel
Schepers, Tim - Abstract:
- Abstract: Background: There is an increasing incidence of fragility fractures of the ankle in the elderly population. The open reduction and internal fixation of these fractures is challenging, due to reduced bone stock quality as a result of osteoporosis. Biomechanical studies have shown contradicting results using reinforced constructions in the fixation of fibular fractures. We therefore performed a meta-analysis of biomechanical studies on reinforced fixation of distal fibular fractures. Methods: A literature search was conducted utilizing three online databases considering biomechanical testing of different fixation techniques of distal fibular fractures. A meta-analysis was performed on two biomechanical outcome measures; torsional stiffness and torque to failure. Findings: In a total number of 13 studies 8 different reinforcement techniques were identified. Of these studies, six compared locked lateral plating with conventional lateral plating. There were no statistically significant differences between the locking and non-locking lateral plate for torque to failure or torsional stiffness. Locked plating strength was independent from bone mineral density in four studies. An antiglide plate proved to be biomechanically superior compared to a lateral plate in one study and to a locked plate in another. Interpretation: Locked lateral plates are not biomechanically superior to conventional lateral plates. However the strength of locked plating may be independent of boneAbstract: Background: There is an increasing incidence of fragility fractures of the ankle in the elderly population. The open reduction and internal fixation of these fractures is challenging, due to reduced bone stock quality as a result of osteoporosis. Biomechanical studies have shown contradicting results using reinforced constructions in the fixation of fibular fractures. We therefore performed a meta-analysis of biomechanical studies on reinforced fixation of distal fibular fractures. Methods: A literature search was conducted utilizing three online databases considering biomechanical testing of different fixation techniques of distal fibular fractures. A meta-analysis was performed on two biomechanical outcome measures; torsional stiffness and torque to failure. Findings: In a total number of 13 studies 8 different reinforcement techniques were identified. Of these studies, six compared locked lateral plating with conventional lateral plating. There were no statistically significant differences between the locking and non-locking lateral plate for torque to failure or torsional stiffness. Locked plating strength was independent from bone mineral density in four studies. An antiglide plate proved to be biomechanically superior compared to a lateral plate in one study and to a locked plate in another. Interpretation: Locked lateral plates are not biomechanically superior to conventional lateral plates. However the strength of locked plating may be independent of bone mineral density and could make this technique more suitable in the fixation of severe osteoporotic fractures. Highlights: Locked lateral plates are biomechanically not superior to regular lateral plates. Locked plating could be independent of bone mineral density. An antiglide plate could be a cheap alternative in fixating fragility ankle fractures. Other viable techniques need to be evaluated biomechanically. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 36(2016)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 36(2016)
- Issue Display:
- Volume 36, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 36
- Issue:
- 2016
- Issue Sort Value:
- 2016-0036-2016-0000
- Page Start:
- 14
- Page End:
- 20
- Publication Date:
- 2016-07
- Subjects:
- Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2016.05.006 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1831.xml