Third trimester placental volume and biometry measurement: A method-development study. (June 2016)
- Record Type:
- Journal Article
- Title:
- Third trimester placental volume and biometry measurement: A method-development study. (June 2016)
- Main Title:
- Third trimester placental volume and biometry measurement: A method-development study
- Authors:
- Higgins, L.E.
Simcox, L.
Sibley, C.P.
Heazell, A.E.P.
Johnstone, E.D. - Abstract:
- Abstract: Objectives: To test the hypothesis that third trimester placental biometry and volume can be measured by two-dimensional (2D) and three-dimensional (3D) ultrasound in utero, determining which method of measurement was most strongly correlated with true placental size ex vivo . Methods: Singleton pregnancies underwent placental ultrasound within seven days of delivery (n = 87, 29 +3 –41 +5 weeks). Length and width (linear and curvilinear) and depth were estimated. Placental volume (PV) was estimated using 2D ellipse and shell techniques and 3D rotational (15⁰ and 30⁰ rotation angles) and multiplanar (5 and 10 mm slicing intervals) techniques. Measurements were compared to their true correlates following delivery. Intra- and inter-observer reliabilities of candidate placental size estimates were assessed by intraclass correlation coefficient (ICC). Results: Curvilinear placental length (Rs = 0.24, p = 0.031), width (Rs = 0.27, p = 0.013) and depth (Rs = 0.31, p = 0.0056) correlated well with ex vivo measurements. All methods of PV estimation were related to ex vivo volume (Rs ≥ 0.32, p < 0.01) but not placental weight (p > 0.05); 30° rotational estimation demonstrated the strongest biological correlation (Rs = 0.40, p = 0.0004). Intra- and inter-observer placental size measurements intraclass correlation coefficients were suboptimal (0.59–0.70 and 0.10–0.58 respectively). Discussion: We have demonstrated that it is possible to obtain information about the sizeAbstract: Objectives: To test the hypothesis that third trimester placental biometry and volume can be measured by two-dimensional (2D) and three-dimensional (3D) ultrasound in utero, determining which method of measurement was most strongly correlated with true placental size ex vivo . Methods: Singleton pregnancies underwent placental ultrasound within seven days of delivery (n = 87, 29 +3 –41 +5 weeks). Length and width (linear and curvilinear) and depth were estimated. Placental volume (PV) was estimated using 2D ellipse and shell techniques and 3D rotational (15⁰ and 30⁰ rotation angles) and multiplanar (5 and 10 mm slicing intervals) techniques. Measurements were compared to their true correlates following delivery. Intra- and inter-observer reliabilities of candidate placental size estimates were assessed by intraclass correlation coefficient (ICC). Results: Curvilinear placental length (Rs = 0.24, p = 0.031), width (Rs = 0.27, p = 0.013) and depth (Rs = 0.31, p = 0.0056) correlated well with ex vivo measurements. All methods of PV estimation were related to ex vivo volume (Rs ≥ 0.32, p < 0.01) but not placental weight (p > 0.05); 30° rotational estimation demonstrated the strongest biological correlation (Rs = 0.40, p = 0.0004). Intra- and inter-observer placental size measurements intraclass correlation coefficients were suboptimal (0.59–0.70 and 0.10–0.58 respectively). Discussion: We have demonstrated that it is possible to obtain information about the size of the third trimester placenta in utero using 2D and 3D ultrasound. However it is essential that the reliability (particularly interobserver reliability) of these estimates is improved prior to prospective studies to determine their predictive value. Highlights: A consistent density of placental tissue is described. The ellipse is identified as the most appropriate geometric shape for in utero placental volume estimation. Placental size and volume can be measured in utero using two- and three-dimensional ultrasound. Third trimester placental sonographic measurements demonstrate suboptimal reliability. … (more)
- Is Part Of:
- Placenta. Volume 42(2016:Jun.)
- Journal:
- Placenta
- Issue:
- Volume 42(2016:Jun.)
- Issue Display:
- Volume 42 (2016)
- Year:
- 2016
- Volume:
- 42
- Issue Sort Value:
- 2016-0042-0000-0000
- Page Start:
- 51
- Page End:
- 58
- Publication Date:
- 2016-06
- Subjects:
- Placental volume -- Placental weight -- Tissue density -- Two-dimensional ultrasound -- Three-dimensional ultrasound -- VOCAL -- Ellipse
Placenta -- Periodicals
Reproduction -- Periodicals
Placenta -- Periodicals
Placenta -- Périodiques
Reproduction -- Périodiques
612.63 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01434004 ↗
http://www.placentajournal.org/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01434004 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01434004 ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journals/plac/ ↗
http://www.idealibrary.com/cgi-bin/links/toc/plac ↗
http://www.harcourt-international.com/journals ↗ - DOI:
- 10.1016/j.placenta.2016.04.010 ↗
- Languages:
- English
- ISSNs:
- 0143-4004
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6506.800000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 571.xml