A method for the steady-state thermal simulation of district heating systems and model parameters calibration. (15th July 2016)
- Record Type:
- Journal Article
- Title:
- A method for the steady-state thermal simulation of district heating systems and model parameters calibration. (15th July 2016)
- Main Title:
- A method for the steady-state thermal simulation of district heating systems and model parameters calibration
- Authors:
- Wang, Jinda
Zhou, Zhigang
Zhao, Jianing - Abstract:
- Highlights: A novel matrix model of district heating network was proposed. Thermal conditions can be solved analytically and efficiently by matrix operation. The number of uncertain parameters was reduced by an aggregation operation. Model parameters were calibrated by an optimized method using genetic algorithms. After calibration, predicted temperatures fitted well with measured data. Abstract: The steady-state thermal conditions of district heating (DH) systems refer to temperature distribution from production plants to consumers. Mathematical models of such networks can be applied, either for general understanding of the system, or in combination with production planning and optimization. In this study, the DH system configuration was simplified to two basic elements (branches and nodes), and a novel matrix simulation model was proposed. Because of its matrix form, the thermal simulation model can be solved quickly by matrix operations. In addition, this new model can represent the whole structure of a large DH system, and it is therefore, easy to change or add new components to an existing model. However, due to the uncertainty of some model parameters, the differences between predicted and observed temperature are usually unacceptable. Therefore, model parameters require calibration before obtaining useful results from simulation. In order to solve this problem efficiently and precisely, the aggregated heat conduction coefficient of pipelines was developed, which couldHighlights: A novel matrix model of district heating network was proposed. Thermal conditions can be solved analytically and efficiently by matrix operation. The number of uncertain parameters was reduced by an aggregation operation. Model parameters were calibrated by an optimized method using genetic algorithms. After calibration, predicted temperatures fitted well with measured data. Abstract: The steady-state thermal conditions of district heating (DH) systems refer to temperature distribution from production plants to consumers. Mathematical models of such networks can be applied, either for general understanding of the system, or in combination with production planning and optimization. In this study, the DH system configuration was simplified to two basic elements (branches and nodes), and a novel matrix simulation model was proposed. Because of its matrix form, the thermal simulation model can be solved quickly by matrix operations. In addition, this new model can represent the whole structure of a large DH system, and it is therefore, easy to change or add new components to an existing model. However, due to the uncertainty of some model parameters, the differences between predicted and observed temperature are usually unacceptable. Therefore, model parameters require calibration before obtaining useful results from simulation. In order to solve this problem efficiently and precisely, the aggregated heat conduction coefficient of pipelines was developed, which could reduce the number of uncertain parameters significantly. Furthermore, an implicit calibration method was introduced, and it could transfer the calibration problem to a typical programming problem. The optimal parameters of this simulation model can be obtained by minimizing a nonlinear objective function subject to a set of linear constraints with the help of a powerful searching technique (genetic algorithms). Advanced MATLAB Genetic Algorithm Solver was used in order to help program process more convenient. Moreover, the validity of this implicit calibration method was demonstrated by the observed data from a real DH system in Harbin. For uncalibrated model, the average absolute error of supply temperatures at all substations was 1.4 °C. But for calibrated model I and II, the average absolute error of supply temperatures were only 0.2 °C and 0.1 °C, respectively. Therefore, the accuracy of temperature prediction enhanced significantly after calibration and the proposed optimization method was validated. … (more)
- Is Part Of:
- Energy conversion and management. Volume 120(2016)
- Journal:
- Energy conversion and management
- Issue:
- Volume 120(2016)
- Issue Display:
- Volume 120, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 120
- Issue:
- 2016
- Issue Sort Value:
- 2016-0120-2016-0000
- Page Start:
- 294
- Page End:
- 305
- Publication Date:
- 2016-07-15
- Subjects:
- District heating system -- Model calibration -- Temperature simulation -- Parameter uncertainty
Direct energy conversion -- Periodicals
Energy storage -- Periodicals
Energy transfer -- Periodicals
Énergie -- Conversion directe -- Périodiques
Direct energy conversion
Periodicals
621.3105 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01968904 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.enconman.2016.04.074 ↗
- Languages:
- English
- ISSNs:
- 0196-8904
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3747.547000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 907.xml