Smartwatches as chest compression feedback devices: A feasibility study. (June 2016)
- Record Type:
- Journal Article
- Title:
- Smartwatches as chest compression feedback devices: A feasibility study. (June 2016)
- Main Title:
- Smartwatches as chest compression feedback devices: A feasibility study
- Authors:
- Song, Yeongtak
Chee, Youngjoon
Oh, Jaehoon
Ahn, Chiwon
Lim, Tae Ho - Abstract:
- Abstract: Background: Recently, there have been attempts to use smartphones and smartwatches as the feedback devices to improve the quality of chest compressions. In this study, we compared chest compression depth feedback accuracy between a smartphone and a smartwatch in a hands-only cardiopulmonary resuscitation scenario, using a manikin with a displacement sensor system. Methods: Ten basic life support providers participated in this study. Guided by the chest compression depths displayed on the monitor of a laptop, which received data from the manikin, each participant performed 2 min of chest compressions for each target depth (35 mm and 55 mm) on a manikin while gripping a smartphone and wearing a smartwatch. Participants had a rest of 1 h between the instances, and the first target depth was set at random. Each chest compression depth data value from the smartphone and smartwatch and a corresponding reference value from the manikin with the displacement system were recorded. To compare the accuracy between the smartphone and smartwatch, the errors, expressed as the absolute of the differences between the reference and each device, were calculated. Results: At both target depths, the error of the smartwatch were significantly smaller than that of the smartphone (the errors of the smartphone vs. smartwatch at 35 mm: 3.4 (1.3) vs. 2.1 (0.8) mm; p = 0.008; at 55 mm: 5.3 (2.8) vs. 2.3 (0.9) mm; p = 0.023). Conclusion: The smartwatch-based chest compression depth feedbackAbstract: Background: Recently, there have been attempts to use smartphones and smartwatches as the feedback devices to improve the quality of chest compressions. In this study, we compared chest compression depth feedback accuracy between a smartphone and a smartwatch in a hands-only cardiopulmonary resuscitation scenario, using a manikin with a displacement sensor system. Methods: Ten basic life support providers participated in this study. Guided by the chest compression depths displayed on the monitor of a laptop, which received data from the manikin, each participant performed 2 min of chest compressions for each target depth (35 mm and 55 mm) on a manikin while gripping a smartphone and wearing a smartwatch. Participants had a rest of 1 h between the instances, and the first target depth was set at random. Each chest compression depth data value from the smartphone and smartwatch and a corresponding reference value from the manikin with the displacement system were recorded. To compare the accuracy between the smartphone and smartwatch, the errors, expressed as the absolute of the differences between the reference and each device, were calculated. Results: At both target depths, the error of the smartwatch were significantly smaller than that of the smartphone (the errors of the smartphone vs. smartwatch at 35 mm: 3.4 (1.3) vs. 2.1 (0.8) mm; p = 0.008; at 55 mm: 5.3 (2.8) vs. 2.3 (0.9) mm; p = 0.023). Conclusion: The smartwatch-based chest compression depth feedback was more accurate than smartphone-based feedback. … (more)
- Is Part Of:
- Resuscitation. Volume 103(2016)
- Journal:
- Resuscitation
- Issue:
- Volume 103(2016)
- Issue Display:
- Volume 103, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 103
- Issue:
- 2016
- Issue Sort Value:
- 2016-0103-2016-0000
- Page Start:
- 20
- Page End:
- 23
- Publication Date:
- 2016-06
- Subjects:
- CPR -- Chest compression -- Feedback device -- Smartphone -- Smartwatch
Resuscitation -- Periodicals
Resuscitation -- Periodicals
Réanimation -- Périodiques
Electronic journals
616.025 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03009572 ↗
http://www.resuscitationjournal.com/ ↗
http://www.clinicalkey.com/dura/browse/journalIssue/03009572 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/03009572 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.resuscitation.2016.03.014 ↗
- Languages:
- English
- ISSNs:
- 0300-9572
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7785.420000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1310.xml