Effects of lipid extraction and ultrafiltration on stable carbon and nitrogen isotopic compositions of fish bone collagen. (8th June 2016)
- Record Type:
- Journal Article
- Title:
- Effects of lipid extraction and ultrafiltration on stable carbon and nitrogen isotopic compositions of fish bone collagen. (8th June 2016)
- Main Title:
- Effects of lipid extraction and ultrafiltration on stable carbon and nitrogen isotopic compositions of fish bone collagen
- Authors:
- Guiry, Eric J.
Szpak, Paul
Richards, Michael P. - Abstract:
- Abstract : Rationale: Fish bone collagen isotopic measurements are increasingly important in palaeodietary and paleoenvironmental studies yet differences in the chemical and physical properties of fish relative to other vertebrate bones are rarely considered. Lipid content in fish bone, which can exceed 50%, may underlie the poor collagen integrity criteria typically observed in archaeological studies. Methods: We compare stable carbon and nitrogen isotopic and elemental compositions of bone collagen prepared using four different methods from a wide range of modern fish species to: (1) assess the extent to which lipid content influences bone collagen δ 13 C and δ 15 N values, and (2) evaluate the relative efficacy of chemical (2:1 chloroform/methanol) and physical (30 kDa ultrafilters) methods for removing lipids from bones. Results: Lower δ 13 C values were observed when the lipid content exceeded 5% of the initial bone mass. The lipid content did not influence the δ 15 N values. 30 kDa ultrafiltration, a common pretreatment for purifying archaeological collagen, removed fewer lipids and was associated with reduced collagen yields (37% loss) as well as altered amino acid compositions. In contrast, collagen prepared using a 2:1 chloroform/methanol lipid extraction step resulted in significantly improved collagen yields, elemental compositions, and isotopic measurements relative to a control treatment. Conclusions: The chemical lipid extraction method (2:1Abstract : Rationale: Fish bone collagen isotopic measurements are increasingly important in palaeodietary and paleoenvironmental studies yet differences in the chemical and physical properties of fish relative to other vertebrate bones are rarely considered. Lipid content in fish bone, which can exceed 50%, may underlie the poor collagen integrity criteria typically observed in archaeological studies. Methods: We compare stable carbon and nitrogen isotopic and elemental compositions of bone collagen prepared using four different methods from a wide range of modern fish species to: (1) assess the extent to which lipid content influences bone collagen δ 13 C and δ 15 N values, and (2) evaluate the relative efficacy of chemical (2:1 chloroform/methanol) and physical (30 kDa ultrafilters) methods for removing lipids from bones. Results: Lower δ 13 C values were observed when the lipid content exceeded 5% of the initial bone mass. The lipid content did not influence the δ 15 N values. 30 kDa ultrafiltration, a common pretreatment for purifying archaeological collagen, removed fewer lipids and was associated with reduced collagen yields (37% loss) as well as altered amino acid compositions. In contrast, collagen prepared using a 2:1 chloroform/methanol lipid extraction step resulted in significantly improved collagen yields, elemental compositions, and isotopic measurements relative to a control treatment. Conclusions: The chemical lipid extraction method (2:1 chloroform/methanol) performed significantly better than the physical lipid extraction method (30 kDa ultrafilters). Given the high quantities of lipids in fish bones we recommend the inclusion of a chemical lipid extraction step when isolating collagen from modern and archaeological fish bones. Copyright © 2016 John Wiley & Sons, Ltd. … (more)
- Is Part Of:
- Rapid communications in mass spectrometry. Volume 30:Number 13(2016)
- Journal:
- Rapid communications in mass spectrometry
- Issue:
- Volume 30:Number 13(2016)
- Issue Display:
- Volume 30, Issue 13 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 13
- Issue Sort Value:
- 2016-0030-0013-0000
- Page Start:
- 1591
- Page End:
- 1600
- Publication Date:
- 2016-06-08
- Subjects:
- Mass spectrometry -- Periodicals
543.65 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/rcm.7590 ↗
- Languages:
- English
- ISSNs:
- 0951-4198
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7254.440000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 78.xml