Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery: Acute Hemodynamic Assessment by Pressure–Volume Loops. (May 2016)
- Record Type:
- Journal Article
- Title:
- Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery: Acute Hemodynamic Assessment by Pressure–Volume Loops. (May 2016)
- Main Title:
- Simultaneous His Bundle and Left Ventricular Pacing for Optimal Cardiac Resynchronization Therapy Delivery
- Authors:
- Padeletti, Luigi
Pieragnoli, Paolo
Ricciardi, Giuseppe
Innocenti, Lisa
Checchi, Luca
Padeletti, Margherita
Michelucci, Antonio
Picariello, Francesco
Valsecchi, Sergio - Abstract:
- Abstract : Background—: Previous studies have investigated the role of intrinsic conduction in optimizing cardiac resynchronization therapy. We investigated the role of fusing pacing-induced activation and intrinsic conduction in cardiac resynchronization therapy by evaluating the acute hemodynamic effects of simultaneous His-bundle (HIS) and left ventricular (LV) pacing. Methods and Results—: We studied 11 patients with systolic heart failure and left bundle-branch block scheduled for cardiac resynchronization therapy implantation. On implantation, LV pressure–volume data were determined via conductance catheter. Standard leads were placed in the right atrium, at the right ventricular apex, and in a coronary vein. An additional electrode was temporarily positioned in the HIS. The following pacing configurations were systematically assessed: standard biventricular (right ventricular apex+LV), LV-only, HIS, simultaneous HIS and LV (HIS+LV). Each configuration was compared with the AAI mode at multiple atrioventricular delays (AVD). In comparison with the AAI, right ventricular apex+LV and LV-only pacing resulted in improved stroke volume (85±32 mL and 86±33 mL versus 58±23 mL; P <0.001), stroke work, maximum pressure derivative, and systolic dyssynchrony at individually optimized AVD. The optimal AVD was close to the P-H interval in the majority of patients. By contrast, HIS-LV pacing improved hemodynamic indexes at all AVD (stroke volume >76 mL at all fixed intervals andAbstract : Background—: Previous studies have investigated the role of intrinsic conduction in optimizing cardiac resynchronization therapy. We investigated the role of fusing pacing-induced activation and intrinsic conduction in cardiac resynchronization therapy by evaluating the acute hemodynamic effects of simultaneous His-bundle (HIS) and left ventricular (LV) pacing. Methods and Results—: We studied 11 patients with systolic heart failure and left bundle-branch block scheduled for cardiac resynchronization therapy implantation. On implantation, LV pressure–volume data were determined via conductance catheter. Standard leads were placed in the right atrium, at the right ventricular apex, and in a coronary vein. An additional electrode was temporarily positioned in the HIS. The following pacing configurations were systematically assessed: standard biventricular (right ventricular apex+LV), LV-only, HIS, simultaneous HIS and LV (HIS+LV). Each configuration was compared with the AAI mode at multiple atrioventricular delays (AVD). In comparison with the AAI, right ventricular apex+LV and LV-only pacing resulted in improved stroke volume (85±32 mL and 86±33 mL versus 58±23 mL; P <0.001), stroke work, maximum pressure derivative, and systolic dyssynchrony at individually optimized AVD. The optimal AVD was close to the P-H interval in the majority of patients. By contrast, HIS-LV pacing improved hemodynamic indexes at all AVD (stroke volume >76 mL at all fixed intervals and 88±31 mL at optimal interval; all P <0.001). Conclusions—: Standard right ventricular apex+LV and LV-only pacing enhanced systolic function and LV synchrony at individually optimized AVD close to the measured intrinsic P-H interval. By contrast, HIS+LV pacing yielded improvements, regardless of AVD setting. These findings support the hypothesis of the crucial role of intrinsic right ventricular conduction in optimal cardiac resynchronization therapy delivery. … (more)
- Is Part Of:
- Circulation. Volume 9:Number 5(2016)
- Journal:
- Circulation
- Issue:
- Volume 9:Number 5(2016)
- Issue Display:
- Volume 9, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 9
- Issue:
- 5
- Issue Sort Value:
- 2016-0009-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-05
- Subjects:
- CRT -- fusion -- heart failure -- His bundle -- pressure volume loop -- resynchronization
Arrhythmia -- Periodicals
Heart -- Electric properties -- Periodicals
616.128 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=01337493-000000000-00000 ↗
http://circep.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCEP.115.003793 ↗
- Languages:
- English
- ISSNs:
- 1941-3149
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.262500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2204.xml