Hematologic reference intervals for Xenopus tropicalis with partial use of automatic counting methods and reliability of long‐term stored samples. (3rd May 2016)
- Record Type:
- Journal Article
- Title:
- Hematologic reference intervals for Xenopus tropicalis with partial use of automatic counting methods and reliability of long‐term stored samples. (3rd May 2016)
- Main Title:
- Hematologic reference intervals for Xenopus tropicalis with partial use of automatic counting methods and reliability of long‐term stored samples
- Authors:
- Maxham, Lily A.
Forzán, María J.
Hogan, Natacha S.
Vanderstichel, Raphaël V.
Gilroy, Cornelia V. - Abstract:
- Abstract : Background: The African frog, Xenopus tropicalis, is widely used in biomedical and toxicologic research. Reference intervals (RI) for hematologic variables, valuable to research and health status assessment, have not been established. Objectives: The purpose of the study was to determine hematologic RI of X tropicalis, and establish whether automated cell counting can facilitate routine hematologic assessment in frogs. Methods: Blood from 41 adult healthy X tropicalis was collected via cardiac puncture, and diluted in Natt–Herrick solution. Complete WBC, RBC, and thrombocyte counts (hemocytometry), differential WBC counts (Wright–Giemsa‐stained smears), PCV (centrifugation), total protein (refractometry), and automated total cell counts (WBC + RBC + thrombocytes, Sysmex particle counting) were determined. Concordance correlation coefficients calculated the agreement between total cell counts obtained by hemocytometry and automated particle counting, and between total cell counts at collection and after 2 years of storage. Results: Leukocyte morphology was similar to other amphibians and mammals. PCV was similar to other frogs; RBC counts were higher, and MCV was lower than in other frog species. Neutrophils were the most numerous WBC. Agreement was good between hemocytometry and automated cell counts. Subtracting the hemocytometer WBC and thrombocyte counts from the automated total cell count reliably yielded the RBC count. Cellular integrity evaluated 2 yearsAbstract : Background: The African frog, Xenopus tropicalis, is widely used in biomedical and toxicologic research. Reference intervals (RI) for hematologic variables, valuable to research and health status assessment, have not been established. Objectives: The purpose of the study was to determine hematologic RI of X tropicalis, and establish whether automated cell counting can facilitate routine hematologic assessment in frogs. Methods: Blood from 41 adult healthy X tropicalis was collected via cardiac puncture, and diluted in Natt–Herrick solution. Complete WBC, RBC, and thrombocyte counts (hemocytometry), differential WBC counts (Wright–Giemsa‐stained smears), PCV (centrifugation), total protein (refractometry), and automated total cell counts (WBC + RBC + thrombocytes, Sysmex particle counting) were determined. Concordance correlation coefficients calculated the agreement between total cell counts obtained by hemocytometry and automated particle counting, and between total cell counts at collection and after 2 years of storage. Results: Leukocyte morphology was similar to other amphibians and mammals. PCV was similar to other frogs; RBC counts were higher, and MCV was lower than in other frog species. Neutrophils were the most numerous WBC. Agreement was good between hemocytometry and automated cell counts. Subtracting the hemocytometer WBC and thrombocyte counts from the automated total cell count reliably yielded the RBC count. Cellular integrity evaluated 2 years post collection was good, and automated counts were not clinically different from counts at collection. Conclusion: We provide hematologic RI for X tropicalis, suggest how automated cell counts may facilitate hematologic assessments of frogs, and establish that blood in Natt–Herrick solution is stable 2 years post collection. … (more)
- Is Part Of:
- Veterinary clinical pathology. Volume 45:Number 2(2016)
- Journal:
- Veterinary clinical pathology
- Issue:
- Volume 45:Number 2(2016)
- Issue Display:
- Volume 45, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 45
- Issue:
- 2
- Issue Sort Value:
- 2016-0045-0002-0000
- Page Start:
- 291
- Page End:
- 299
- Publication Date:
- 2016-05-03
- Subjects:
- Automated counts -- blood -- long‐term storage -- reference intervals -- Xenopus tropicalis
Veterinary pathology -- Periodicals
636.089607 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/vcp.12362 ↗
- Languages:
- English
- ISSNs:
- 0275-6382
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 9227.015500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 219.xml