Respiration artifact correction in three‐dimensional proton resonance frequency MR thermometry using phase navigators. Issue 1 (13th August 2015)
- Record Type:
- Journal Article
- Title:
- Respiration artifact correction in three‐dimensional proton resonance frequency MR thermometry using phase navigators. Issue 1 (13th August 2015)
- Main Title:
- Respiration artifact correction in three‐dimensional proton resonance frequency MR thermometry using phase navigators
- Authors:
- Svedin, Bryant T.
Payne, Allison
Parker, Dennis L. - Abstract:
- Abstract : Purpose: To develop reliable three‐dimensional (3D) segmented echo planar imaging (seg‐EPI) proton resonance frequency (PRF) temperature monitoring in the presence of respiration‐induced B0 variation. Methods: A free induction decay (FID) phase navigator was inserted into a 3D seg‐EPI sequence before and after EPI readout to monitor B0 field variations. Using the field change estimates, the phase of each k‐space line was adjusted to remove the additional phase from the respiratory induced off‐resonance. This correction technique was evaluated while heating with MR‐guided focused ultrasound (MRgFUS) in phantoms with simulated breathing and during nonheating conditions in healthy in vivo breasts. Results: With k‐space phase correction, the standard deviation of magnitude images and PRF temperature measurements in breast from five volunteers improved by an average factor of 1.5 and 2.1, respectively. Improved accuracy of temperature estimates was observed after correction while heating with MRgFUS in phantoms. Conclusion: Phase correction based on two FID navigators placed before and after the echo train provides promising results for implementing 3D monitoring of thermal therapy treatments in the presence of field variations due to respiration. Magn Reson Med 76:206–213, 2016. © 2015 Wiley Periodicals, Inc.
- Is Part Of:
- Magnetic resonance in medicine. Volume 76:Issue 1(2016)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 76:Issue 1(2016)
- Issue Display:
- Volume 76, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 76
- Issue:
- 1
- Issue Sort Value:
- 2016-0076-0001-0000
- Page Start:
- 206
- Page End:
- 213
- Publication Date:
- 2015-08-13
- Subjects:
- PRF temperature -- respiration correction -- phase navigator
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25860 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 369.xml