Diffusional kurtosis imaging for differentiating between high‐grade glioma and primary central nervous system lymphoma. Issue 1 (20th November 2015)
- Record Type:
- Journal Article
- Title:
- Diffusional kurtosis imaging for differentiating between high‐grade glioma and primary central nervous system lymphoma. Issue 1 (20th November 2015)
- Main Title:
- Diffusional kurtosis imaging for differentiating between high‐grade glioma and primary central nervous system lymphoma
- Authors:
- Pang, Haopeng
Ren, Yan
Dang, Xuefei
Feng, Xiaoyuan
Yao, Zhenwei
Wu, Jingsong
Yao, Chengjun
DI, Ning
Ghinda, Diana Cristina
Zhang, Yong - Abstract:
- Abstract : Background: The aim of this study was to assess the diagnostic accuracy of diffusion kurtosis magnetic resonance imaging parameters for differentiating high‐grade gliomas (HGGs) from primary central nervous system lymphomas (PCNSLs). Methods: Diffusion parameters, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (λ// ), radial diffusivity (λ⊥ ); and kurtosis parameters, including mean kurtosis (MK), axial kurtosis (K// ), and radial kurtosis (K⊥ ), were normalized to contralateral normal‐appearing white matter (NAWMc) to decrease inter‐individual and inter‐regional changes across the entire brain, and then compared with the solid parts of 20 HGGs and 11 PCNSLs [median 95% confidence interval (CI), P < 0.004; 0.05/14], significance level, Kolmogorov‐Smirnov test, Bonferroni correction]. Results: FA, MD, λ//, and λ⊥ values were higher in HGGs than in PCNSLs, but not significantly [HGGs: 0.209 (95% CI, 0.134–0.338), 1.385 (95% CI, 1.05–1.710), 1.655 (95% CI, 1.30–2.060), 1.228 (95% CI, 0.932–1.480), respectively; PCNSLs: 0.143 (95% CI, 0.110–0.317), 1.070 (95% CI, 0.842–1.470), 1.260 (95% CI, 0.960–1.930), 1.010 (95% CI, 0.782–1.240)], respectively; P = 0.120, 0.010, 0.004, and 0.004, respectively). However, MK and K// were significantly higher in PCNSLs compared with HGGs [PCNSLs: 0.765 (95% CI, 0.697–0.890), 0.787 (95% CI, 0.615–1.030), respectively; HGGs: 0.531 (95% CI, 0.402–0.766), 0.532 (95% CI, 0.432–0.680], respectively; PAbstract : Background: The aim of this study was to assess the diagnostic accuracy of diffusion kurtosis magnetic resonance imaging parameters for differentiating high‐grade gliomas (HGGs) from primary central nervous system lymphomas (PCNSLs). Methods: Diffusion parameters, including fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (λ// ), radial diffusivity (λ⊥ ); and kurtosis parameters, including mean kurtosis (MK), axial kurtosis (K// ), and radial kurtosis (K⊥ ), were normalized to contralateral normal‐appearing white matter (NAWMc) to decrease inter‐individual and inter‐regional changes across the entire brain, and then compared with the solid parts of 20 HGGs and 11 PCNSLs [median 95% confidence interval (CI), P < 0.004; 0.05/14], significance level, Kolmogorov‐Smirnov test, Bonferroni correction]. Results: FA, MD, λ//, and λ⊥ values were higher in HGGs than in PCNSLs, but not significantly [HGGs: 0.209 (95% CI, 0.134–0.338), 1.385 (95% CI, 1.05–1.710), 1.655 (95% CI, 1.30–2.060), 1.228 (95% CI, 0.932–1.480), respectively; PCNSLs: 0.143 (95% CI, 0.110–0.317), 1.070 (95% CI, 0.842–1.470), 1.260 (95% CI, 0.960–1.930), 1.010 (95% CI, 0.782–1.240)], respectively; P = 0.120, 0.010, 0.004, and 0.004, respectively). However, MK and K// were significantly higher in PCNSLs compared with HGGs [PCNSLs: 0.765 (95% CI, 0.697–0.890), 0.787 (95% CI, 0.615–1.030), respectively; HGGs: 0.531 (95% CI, 0.402–0.766), 0.532 (95% CI, 0.432–0.680], respectively; P = 0.001, 0.000, respectively); but not K⊥ [0.774 (95% CI, 0.681–0.899) for PCNSLs; 0.554 (95% CI, 0.389−0.954) for HGGs; P = 0.024]. Conclusion: There were significant differences in kurtosis parameters (MK and K// ) between HGGs and PCNSLs, while differences in diffusion parameters between them did not reach significance; hence, better separation was achieved with these parameters than with conventional diffusion imaging parameters. J. Magn. Reson. Imaging 2016;44:30–40. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 1(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 1(2016)
- Issue Display:
- Volume 44, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2016-0044-0001-0000
- Page Start:
- 30
- Page End:
- 40
- Publication Date:
- 2015-11-20
- Subjects:
- diffusion kurtosis imaging -- high‐grade glioma -- primary central nervous system lymphoma
Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25090 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 938.xml