Performance tests of a large volume cerium tribromide (CeBr3) scintillation detector. (August 2016)
- Record Type:
- Journal Article
- Title:
- Performance tests of a large volume cerium tribromide (CeBr3) scintillation detector. (August 2016)
- Main Title:
- Performance tests of a large volume cerium tribromide (CeBr3) scintillation detector
- Authors:
- Naqvi, A.A.
Khiari, F.Z.
Liadi, F.A.
Khateeb-ur-Rehman,
Isab, A.A. - Abstract:
- Abstract: The response of a large cylindrical 76 mm×76 mm (height×diameter) cerium tribromide (CeBr3 ) detector was measured for prompt gamma rays. The total intrinsic activity of the CeBr3 detector, which was measured over 0.33–3.33 MeV range, was found to be 0.022±0.001 counts/s/cm 3 . The partial intrinsic activity ( due to 227 Ac contamination), was measured over a energy range of 1.22–2.20 MeV energy, was found to be 0.007±0.001 counts/s/cm 3 . Compared to intrinsic activities of LaBr3 :Ce and LaCl3 :Ce detectors of equivalent volume, the CeBr3 detector has 7–8 times less total intrinsic activity. The detector response for low energy prompt gamma rays was measured over 0.3–0.6 MeV gamma energy range using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. The experimental yield of boron, cadmium and mercury prompt gamma-rays was measured from water samples contaminated with 0.75–2.5 wt% mercury, 0.31–2.50 wt% boron, and 0.0625–0.500 wt% cadmium, respectively. An excellent agreement has been observed between the calculated and experimental yields of the gamma rays. Also minimum detection limit (MDC) of the CeBr3 detector was measured for boron, cadmium and mercury samples. The CeBr3 detector has 23% smaller value of MDCB and 18% larger value of MDCCd than those of a LaBr3 :Ce detector of equivalent size. This study has shown that CeBr3 detector has an excellent response for the low energy prompt gamma-rays with almost an order ofAbstract: The response of a large cylindrical 76 mm×76 mm (height×diameter) cerium tribromide (CeBr3 ) detector was measured for prompt gamma rays. The total intrinsic activity of the CeBr3 detector, which was measured over 0.33–3.33 MeV range, was found to be 0.022±0.001 counts/s/cm 3 . The partial intrinsic activity ( due to 227 Ac contamination), was measured over a energy range of 1.22–2.20 MeV energy, was found to be 0.007±0.001 counts/s/cm 3 . Compared to intrinsic activities of LaBr3 :Ce and LaCl3 :Ce detectors of equivalent volume, the CeBr3 detector has 7–8 times less total intrinsic activity. The detector response for low energy prompt gamma rays was measured over 0.3–0.6 MeV gamma energy range using a portable neutron generator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup. The experimental yield of boron, cadmium and mercury prompt gamma-rays was measured from water samples contaminated with 0.75–2.5 wt% mercury, 0.31–2.50 wt% boron, and 0.0625–0.500 wt% cadmium, respectively. An excellent agreement has been observed between the calculated and experimental yields of the gamma rays. Also minimum detection limit (MDC) of the CeBr3 detector was measured for boron, cadmium and mercury samples. The CeBr3 detector has 23% smaller value of MDCB and 18% larger value of MDCCd than those of a LaBr3 :Ce detector of equivalent size. This study has shown that CeBr3 detector has an excellent response for the low energy prompt gamma-rays with almost an order of magnitude low intrinsic activity as compared to LaCl3 :Ce and LaBr3 :Ce detectors of equivalent volume. Highlights: Pulse height tests of large diameter CeBr3 detector for low energy gamma rays using portable neutron generator based PGNAA setup. CeBr3 detector has 7–8 times less total intrinsic activity than that of a LaBr3 :Ce or LaCl3 :Ce detector. The CeBr3 detector has 23% smaller MDCB and 18% larger MDCCd than those of a LaBr3:Ce detector. … (more)
- Is Part Of:
- Applied radiation and isotopes. Volume 114(2016:Aug.)
- Journal:
- Applied radiation and isotopes
- Issue:
- Volume 114(2016:Aug.)
- Issue Display:
- Volume 114 (2016)
- Year:
- 2016
- Volume:
- 114
- Issue Sort Value:
- 2016-0114-0000-0000
- Page Start:
- 50
- Page End:
- 56
- Publication Date:
- 2016-08
- Subjects:
- CeBr3 detector performance tests -- Portable neutron generator based PGNAA setup -- CeBr3 detector -- Prompt gamma measurements -- Boron, cadmium and mercury contaminated water samples -- Minimum detection limit of boron, cadmium and mercury in water sample
Radiology -- Periodicals
Radiation -- Industrial applications -- Periodicals
Nuclear chemistry -- Periodicals
Internet resource
Periodical
660.298 - Journal URLs:
- http://www.sciencedirect.com/science/journal/09698043 ↗
http://catalog.hathitrust.org/api/volumes/oclc/27456684.html ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.apradiso.2016.04.031 ↗
- Languages:
- English
- ISSNs:
- 0969-8043
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1576.565000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2008.xml