Evaluating the diagnostic sensitivity of computed diffusion‐weighted MR imaging in the detection of breast cancer. Issue 1 (13th January 2016)
- Record Type:
- Journal Article
- Title:
- Evaluating the diagnostic sensitivity of computed diffusion‐weighted MR imaging in the detection of breast cancer. Issue 1 (13th January 2016)
- Main Title:
- Evaluating the diagnostic sensitivity of computed diffusion‐weighted MR imaging in the detection of breast cancer
- Authors:
- O'Flynn, Elizabeth A.M.
Blackledge, Matthew
Collins, David
Downey, Katherine
Doran, Simon
Patel, Hardik
Dumonteil, Sam
Mok, Wing
Leach, Martin O
Koh, Dow‐Mu - Abstract:
- Abstract : Purpose: To evaluate the diagnostic sensitivity of computed diffusion‐weighted (DW)‐MR imaging for the detection of breast cancer. Materials and Methods: Local research ethics approval was obtained. A total of 61 women (median 48 years) underwent dynamic contrast enhanced (DCE)‐ and DW‐MR between January 2011 and March 2012, including 27 with breast cancer on core biopsy and 34 normal cases. Standard ADC maps using all four b values (0, 350, 700, 1150) were used to generate computed DW‐MR images at b = 1500 s/mm 2 and b = 2000 s/mm 2 . Four image sets were read sequentially by two readers: acquired b = 1150 s/mm 2, computed b = 1500 s/mm 2 and b = 2000 s/mm 2, and DCE‐MR at an early time point. Cancer detection was rated using a five‐point scale; image quality and background suppression were rated using a four‐point scale. The diagnostic sensitivity for breast cancer detection was compared using the McNemar test and inter‐reader agreement with a Kappa value. Results: Computed DW‐MR resulted in higher overall diagnostic sensitivity with b = 2000 s/mm 2 having a mean diagnostic sensitivity of 76% (range 49.8‐93.7%) and b = 1500 s/mm 2 having a mean diagnostic sensitivity of 70.3% (range 32‐97.7%) compared with 44.4% (range 25.5‐64.7%) for acquired b = 1150 s/mm 2 (both p = 0.0001). Computed DW‐MR images produced better image quality and background suppression (mean scores for both readers: 2.55 and 2.9 for b 1500 s/mm 2 ; 2.55 and 3.15 for b 2000 s/mm 2,Abstract : Purpose: To evaluate the diagnostic sensitivity of computed diffusion‐weighted (DW)‐MR imaging for the detection of breast cancer. Materials and Methods: Local research ethics approval was obtained. A total of 61 women (median 48 years) underwent dynamic contrast enhanced (DCE)‐ and DW‐MR between January 2011 and March 2012, including 27 with breast cancer on core biopsy and 34 normal cases. Standard ADC maps using all four b values (0, 350, 700, 1150) were used to generate computed DW‐MR images at b = 1500 s/mm 2 and b = 2000 s/mm 2 . Four image sets were read sequentially by two readers: acquired b = 1150 s/mm 2, computed b = 1500 s/mm 2 and b = 2000 s/mm 2, and DCE‐MR at an early time point. Cancer detection was rated using a five‐point scale; image quality and background suppression were rated using a four‐point scale. The diagnostic sensitivity for breast cancer detection was compared using the McNemar test and inter‐reader agreement with a Kappa value. Results: Computed DW‐MR resulted in higher overall diagnostic sensitivity with b = 2000 s/mm 2 having a mean diagnostic sensitivity of 76% (range 49.8‐93.7%) and b = 1500 s/mm 2 having a mean diagnostic sensitivity of 70.3% (range 32‐97.7%) compared with 44.4% (range 25.5‐64.7%) for acquired b = 1150 s/mm 2 (both p = 0.0001). Computed DW‐MR images produced better image quality and background suppression (mean scores for both readers: 2.55 and 2.9 for b 1500 s/mm 2 ; 2.55 and 3.15 for b 2000 s/mm 2, respectively) than the acquired b value 1150 s/mm 2 images (mean scores for both readers: 2.4 and 2.45, respectively). Conclusion: Computed DW‐MR imaging has the potential to improve the diagnostic sensitivity of breast cancer detection compared to acquired DW‐MR. J. Magn. Reson. Imaging 2016;44:130–137. … (more)
- Is Part Of:
- Journal of magnetic resonance imaging. Volume 44:Issue 1(2016)
- Journal:
- Journal of magnetic resonance imaging
- Issue:
- Volume 44:Issue 1(2016)
- Issue Display:
- Volume 44, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 44
- Issue:
- 1
- Issue Sort Value:
- 2016-0044-0001-0000
- Page Start:
- 130
- Page End:
- 137
- Publication Date:
- 2016-01-13
- Subjects:
- Magnetic resonance imaging -- Periodicals
616 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2586 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jmri.25131 ↗
- Languages:
- English
- ISSNs:
- 1053-1807
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5010.791000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 938.xml