An HPLC method with diode array detector for the simultaneous quantification of chloroquine and desethylchloroquine in plasma and whole blood samples from Plasmodium vivax patients in Vietnam, using quinine as an internal standard. (5th January 2016)
- Record Type:
- Journal Article
- Title:
- An HPLC method with diode array detector for the simultaneous quantification of chloroquine and desethylchloroquine in plasma and whole blood samples from Plasmodium vivax patients in Vietnam, using quinine as an internal standard. (5th January 2016)
- Main Title:
- An HPLC method with diode array detector for the simultaneous quantification of chloroquine and desethylchloroquine in plasma and whole blood samples from Plasmodium vivax patients in Vietnam, using quinine as an internal standard
- Authors:
- Van Pham, Toi
Pham Nguyen, Phuong
Nguyen Duc Khanh, Tho
Nguyen Thanh Thuy, Nhien
Nguyen Thuy Nha, Ca
Pouplin, Thomas
Farrar, Jeremy
Thwaites, Guy E.
Tran Tinh, Hien - Abstract:
- Abstract: A sensitive, simple method for quantification of chloroquine (CQ) and desethylchloroquine (MCQ) in whole blood and plasma from Plasmodium vivax patients has been developed using HPLC with diode array detection (DAD). Solid‐phase extraction on Isolute‐96‐CBA was employed to process 100 μL of plasma/whole blood samples. CQ, MCQ and quinine were separated using a mobile phase of phosphate buffer 25 mm, pH 2.60–acetonitrile (88:12, v / v ) with 2 mm sodium perchlorate on a Zorbax SB‐CN 150 × 4.6 mm, 5 μm column at a flow rate of 1.2 mL/min, at ambient temperature in 10 min, with the DAD wavelength of 343 nm. The method was linear over the range of 10–5000 ng/mL for both CQ and MCQ in plasma and whole blood. The limit of detection was 4 ng/mL and limit of quantification was 10 ng/mL in both plasma and blood for CQ and MCQ. The intra‐, inter‐ and total assay precision were <10% for CQ and MCQ in plasma and whole blood. In plasma, the accuracies varied between 101 and 103%, whereas in whole blood, the accuracies ranged from 97.0 to 102% for CQ and MCQ. The method is an ideal technique with simple facilities and instruments, bringing about good separation in comparison with previous methods. © 2016 The Authors Biomedical Chromatography Published by John Wiley & Sons Ltd
- Is Part Of:
- Biomedical chromatography. Volume 30:Number 7(2016:Jul.)
- Journal:
- Biomedical chromatography
- Issue:
- Volume 30:Number 7(2016:Jul.)
- Issue Display:
- Volume 30, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 30
- Issue:
- 7
- Issue Sort Value:
- 2016-0030-0007-0000
- Page Start:
- 1104
- Page End:
- 1111
- Publication Date:
- 2016-01-05
- Subjects:
- HPLC‐DAD -- SPE -- chloroquine -- desethylchloroquine -- Plasmodium vivax -- malaria
Chromatographic analysis -- Periodicals
Biology -- Periodicals
Medicine -- Periodicals
Biology -- Periodicals
Chromatography -- methods -- Periodicals
Medicine -- Periodicals
543.089 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/bmc.3657 ↗
- Languages:
- English
- ISSNs:
- 0269-3879
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.758000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2001.xml