A study of polymerization shrinkage kinetics using digital image correlation. Issue 4 (April 2015)
- Record Type:
- Journal Article
- Title:
- A study of polymerization shrinkage kinetics using digital image correlation. Issue 4 (April 2015)
- Main Title:
- A study of polymerization shrinkage kinetics using digital image correlation
- Authors:
- Lau, Andrew
Li, Jianying
Heo, Young Cheul
Fok, Alex - Abstract:
- Highlights: A technique for measuring real-time shrinkage strain in composite resin is proposed. An inversely synchronized external shutter allows for measurement during irradiation. Polymerization shrinkage kinetics parameters are calculated for Filtek LS and Z100. Full-field strain contour plots and shrinkage strain time series are presented. Abstract: Objective: To investigate the polymerization shrinkage kinetics of dental resin composites by measuring in real time the full-field shrinkage strain using a novel technique based on digital image correlation (DIC). Methods: Polymerization shrinkage in resin composite specimens (Filtek LS and Z100) was measured as a function of time and position. The main experimental setup included a CCD camera and an external shutter inversely synchronized to that of the camera. The specimens (2 mm × 4 mm × 5 mm) were irradiated for 40 s at 1200 mW/cm 2, while alternating image acquisition and obstruction of the curing light occurred at 15 fps. The acquired images were processed using proprietary software to obtain the full-field strain maps as a function of time. Results: Z100 showed a higher final shrinkage value and rate of development than LS. The final volumetric shrinkage for Z100 and LS were 1.99% and 1.19%, respectively. The shrinkage behavior followed an established shrinkage strain kinetics model. The corresponding characteristic time and reaction order exponent for LS and Z100 were calculated to be approximately 23 s and 0.84,Highlights: A technique for measuring real-time shrinkage strain in composite resin is proposed. An inversely synchronized external shutter allows for measurement during irradiation. Polymerization shrinkage kinetics parameters are calculated for Filtek LS and Z100. Full-field strain contour plots and shrinkage strain time series are presented. Abstract: Objective: To investigate the polymerization shrinkage kinetics of dental resin composites by measuring in real time the full-field shrinkage strain using a novel technique based on digital image correlation (DIC). Methods: Polymerization shrinkage in resin composite specimens (Filtek LS and Z100) was measured as a function of time and position. The main experimental setup included a CCD camera and an external shutter inversely synchronized to that of the camera. The specimens (2 mm × 4 mm × 5 mm) were irradiated for 40 s at 1200 mW/cm 2, while alternating image acquisition and obstruction of the curing light occurred at 15 fps. The acquired images were processed using proprietary software to obtain the full-field strain maps as a function of time. Results: Z100 showed a higher final shrinkage value and rate of development than LS. The final volumetric shrinkage for Z100 and LS were 1.99% and 1.19%, respectively. The shrinkage behavior followed an established shrinkage strain kinetics model. The corresponding characteristic time and reaction order exponent for LS and Z100 were calculated to be approximately 23 s and 0.84, and 14 s and 0.7, respectively, at a distance of 1.0 mm from the irradiated surface, the position where maximum shrinkage strain occurred. Thermal expansion from the exothermic reaction could have affected the accuracy of these parameters. Significance: The new DIC method using an inversely synchronized shutter provided realtime, full-field results that could aid in assessing the shrinkage strain kinetics of dental resin composites as a function of specimen depth. It could also help determine the optimal curing modes for dental resin composites. … (more)
- Is Part Of:
- Dental materials. Volume 31:Issue 4(2015)
- Journal:
- Dental materials
- Issue:
- Volume 31:Issue 4(2015)
- Issue Display:
- Volume 31, Issue 4 (2015)
- Year:
- 2015
- Volume:
- 31
- Issue:
- 4
- Issue Sort Value:
- 2015-0031-0004-0000
- Page Start:
- 391
- Page End:
- 398
- Publication Date:
- 2015-04
- Subjects:
- Resin composite -- Polymerization shrinkage kinetics -- Digital image correlation (DIC) -- Inversely synchronized shutter -- Real-time measurement
Dentistry -- Periodicals
Dental materials -- Periodicals
617.695 - Journal URLs:
- http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science/journal/01095641/ ↗ - DOI:
- 10.1016/j.dental.2015.01.001 ↗
- Languages:
- English
- ISSNs:
- 0109-5641
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3553.365800
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2665.xml