Exercise and Repeated Testing Improves Accuracy of Laser Doppler Assessment of Microvascular Function Following Shortened (1‐minute) Blood Flow Occlusion. (May 2016)
- Record Type:
- Journal Article
- Title:
- Exercise and Repeated Testing Improves Accuracy of Laser Doppler Assessment of Microvascular Function Following Shortened (1‐minute) Blood Flow Occlusion. (May 2016)
- Main Title:
- Exercise and Repeated Testing Improves Accuracy of Laser Doppler Assessment of Microvascular Function Following Shortened (1‐minute) Blood Flow Occlusion
- Authors:
- Tran, Brian D.
Chiu, Abraham
Tran, Charlene
Rogacion, Danica Rose
Tfaye, Nicole
Ganesan, Goutham
Galassetti, Pietro R. - Abstract:
- Abstract: Objectives: To determine whether stability/accuracy of post‐occlusive LDF following shortened, one‐minute blood flow occlusion, increases in the post‐exercise state or by averaging multiple measurements. Methods: Six healthy adults (3F) underwent LDF eight times at rest and following exercise, assessing post‐occlusive (one‐minute occlusion) reactive hyperemia in the cutaneous microcirculation of the forefinger. Measured variables included: pre‐ and post‐occlusion steady‐state perfusion (Plat1, Plat2), maximum post‐occlusive perfusion (Max), PkT, and the ratio Max/Plat1. Results: Stability/accuracy of all variables improved performing measurements after exercise ( p < 0.05 Plat 1, Plat 2, Max and Max/Plat1). PkT and Max/Plat 1 displayed the greatest accuracy at rest (26.6 ± 5.1% and 26.6 ± 4.4% average difference, %Diff, of single measurements from individual "true" means, respectively); for these variables, %Diff improved to 19.5 ± 5.3 and 17.6 ± 2.1, respectively, following exercise. Overall, averaging multiple measurements performed at rest also improved stability/accuracy in all variables. This improvement was comparable to that obtained with a single measurement following exercise. Conclusions: A standardized exercise stimulus prior to testing significantly improves stability/accuracy of LDF following shortened, one‐minute blood flow occlusion. Our results suggest the possibilities of broader applications of exercise to optimize measurements from a variety ofAbstract: Objectives: To determine whether stability/accuracy of post‐occlusive LDF following shortened, one‐minute blood flow occlusion, increases in the post‐exercise state or by averaging multiple measurements. Methods: Six healthy adults (3F) underwent LDF eight times at rest and following exercise, assessing post‐occlusive (one‐minute occlusion) reactive hyperemia in the cutaneous microcirculation of the forefinger. Measured variables included: pre‐ and post‐occlusion steady‐state perfusion (Plat1, Plat2), maximum post‐occlusive perfusion (Max), PkT, and the ratio Max/Plat1. Results: Stability/accuracy of all variables improved performing measurements after exercise ( p < 0.05 Plat 1, Plat 2, Max and Max/Plat1). PkT and Max/Plat 1 displayed the greatest accuracy at rest (26.6 ± 5.1% and 26.6 ± 4.4% average difference, %Diff, of single measurements from individual "true" means, respectively); for these variables, %Diff improved to 19.5 ± 5.3 and 17.6 ± 2.1, respectively, following exercise. Overall, averaging multiple measurements performed at rest also improved stability/accuracy in all variables. This improvement was comparable to that obtained with a single measurement following exercise. Conclusions: A standardized exercise stimulus prior to testing significantly improves stability/accuracy of LDF following shortened, one‐minute blood flow occlusion. Our results suggest the possibilities of broader applications of exercise to optimize measurements from a variety of skin perfusion methodologies. … (more)
- Is Part Of:
- Microcirculation. Volume 23:Number 4(2016)
- Journal:
- Microcirculation
- Issue:
- Volume 23:Number 4(2016)
- Issue Display:
- Volume 23, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 23
- Issue:
- 4
- Issue Sort Value:
- 2016-0023-0004-0000
- Page Start:
- 293
- Page End:
- 300
- Publication Date:
- 2016-05
- Subjects:
- exercise -- laser Doppler flowmetry -- post‐occlusive reactive hyperemia -- reliability
Biological transport -- Periodicals
Microcirculation -- Physiology -- Periodicals
612.135 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1549-8719/issues ↗
http://onlinelibrary.wiley.com/ ↗
http://informahealthcare.com/loi/mic ↗ - DOI:
- 10.1111/micc.12277 ↗
- Languages:
- English
- ISSNs:
- 1073-9688
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5758.460000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 2679.xml