Monitoring of Intracranial Pressure by CT‐Defined Optic Nerve Sheath Diameter. Issue 3 (21st December 2015)
- Record Type:
- Journal Article
- Title:
- Monitoring of Intracranial Pressure by CT‐Defined Optic Nerve Sheath Diameter. Issue 3 (21st December 2015)
- Main Title:
- Monitoring of Intracranial Pressure by CT‐Defined Optic Nerve Sheath Diameter
- Authors:
- Bekerman, Inessa
Kimiagar, Itzhak
Sigal, Tal
Vaiman, Michael - Abstract:
- ABSTRACT: BACKGROUND AND PURPOSE: Intracranial pressure (ICP) can be monitored by the optic nerve sheath diameter (ONSD) technique. We hypothesized that diameter of the optic canal (OC) can be a limiting factor for this technique. METHODS: In the prospective cohort study, we analyzed CT scans of 600 OCs of healthy adults and 54 canals of patients with ICP monitoring. The diameters were measured through its length and the narrowest one was chosen for further analysis. ONSD was measured at 3 and 10 mm from the anterior opening of the canal. The correlation analysis was performed between invasive and ONSD methods of ICP monitoring and OC diameters in pathological cases. RESULTS: The narrowest cross‐sectional area of the normal OC was 13.85±2.89 mm² and varied from 25.5 to 6.6 mm². Apparently 9.17% OCs were narrow (˂10.9 mm²). Correlations exist between the optic nerve sheath area at the 3‐mm distance from the anterior opening of the canal and the area of the anterior opening itself ( P = .012), and the sheath area 10 mm from the anterior opening and the narrowest part of the canal ( P = .015). Cases with narrow canals provided false‐negative readings via ONSD method if compared with invasive monitoring. CONCLUSION: In its narrowest part, the average OC is 11 to 16.75 mm² wide. We suggest measuring this area simultaneously with the ONSD during ICP monitoring. If the area of the narrowest lumen of the canal is less than 10 mm², ONSD technique for ICP monitoring should not be used.
- Is Part Of:
- Journal of neuroimaging. Volume 26:Issue 3(2016)
- Journal:
- Journal of neuroimaging
- Issue:
- Volume 26:Issue 3(2016)
- Issue Display:
- Volume 26, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 26
- Issue:
- 3
- Issue Sort Value:
- 2016-0026-0003-0000
- Page Start:
- 309
- Page End:
- 314
- Publication Date:
- 2015-12-21
- Subjects:
- Optic canal -- optic nerve sheath diameter -- intracranial pressure monitoring -- CT
Diagnostic imaging -- Periodicals
Nervous system -- Diseases -- Diagnosis -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Système nerveux -- Maladies -- Diagnostic -- Périodiques
Imagerie médicale
Neuroimagerie
Neurologie
Système nerveux
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.804754 - Journal URLs:
- http://jon.sagepub.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1552-6569 ↗
http://www.ingentaconnect.com/content/bpl/jon ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jon.12322 ↗
- Languages:
- English
- ISSNs:
- 1051-2284
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.548000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1310.xml