Characterisation of graphene fibres and graphene coated fibres using capacitively coupled contactless conductivity detector. Issue 9 (25th February 2016)
- Record Type:
- Journal Article
- Title:
- Characterisation of graphene fibres and graphene coated fibres using capacitively coupled contactless conductivity detector. Issue 9 (25th February 2016)
- Main Title:
- Characterisation of graphene fibres and graphene coated fibres using capacitively coupled contactless conductivity detector
- Authors:
- Cabot, Joan M.
Duffy, Emer
Currivan, Sinéad
Ruland, Andres
Jalili, Rouhollah
Mozer, Attila J.
Innis, Peter C.
Wallace, Gordon G.
Breadmore, Michael
Paull, Brett - Abstract:
- Abstract : The use of capacitively coupled contactless conductivity detection (C 4 D) for the characterisation of thin conductive graphene fibres, graphene composite fibres, and graphene coated fibrous materials is demonstrated for the first time. Abstract : The use of capacitively coupled contactless conductivity detection (C 4 D) for the characterisation of thin conductive graphene fibres, graphene composite fibres, and graphene coated fibrous materials is demonstrated for the first time. Within a few seconds, the non-destructive C 4 D detector provides a profile of the longetudinal physical homogeneity of the fibre, as well as extra information regarding fibre mophology and composition. In addition to the theoretical considerations related to the factors affect the output signal, this work evaluates the properties of graphene fibres using scanning C 4 D following the manufacturing process of wet-spinning. Furthermore, conductive graphene-coated fibrous materials and the effectiveness of the coating and reduction procedures applied could be investigated. Apart from the application of C 4 D in the monitoring of such processes, the feasibility of this small, highly sensitive and rapidly-responsive detector to monitor strain and elasticity responses of conductive and elastomeric composite fibres for applications in motion sensing, biomedical monitoring, and stretchable electronics was also demonstrated.
- Is Part Of:
- Analyst. Volume 141:Issue 9(2016)
- Journal:
- Analyst
- Issue:
- Volume 141:Issue 9(2016)
- Issue Display:
- Volume 141, Issue 9 (2016)
- Year:
- 2016
- Volume:
- 141
- Issue:
- 9
- Issue Sort Value:
- 2016-0141-0009-0000
- Page Start:
- 2774
- Page End:
- 2782
- Publication Date:
- 2016-02-25
- Subjects:
- Chemistry, Analytic -- Periodicals
543 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/an?e=1#!issueid=an139020&type=current&issnprint=0003-2654 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/c5an02534f ↗
- Languages:
- English
- ISSNs:
- 0003-2654
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0893.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1859.xml