An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform. (May 2016)
- Record Type:
- Journal Article
- Title:
- An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform. (May 2016)
- Main Title:
- An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform
- Authors:
- Alvarado-Serrano, Carlos
Luna-Lozano, Pablo Samuel
Pallàs-Areny, Ramon - Abstract:
- Highlights: An algorithm for beat-to-beat heart rate detection from the BCG is proposed. BCG is obtained from seated subjects. Algorithm is based on the continuous wavelet transform with splines. Algorithm detects J-wave peak of the BCG for heart rate calculation. Good agreement between heart rates from BCG and standard ECG was obtained. Abstract: This work describes an algorithm intended to detect the beat-to-beat heart rate from the ballistocardiogram (BCG) obtained from seated subjects. The algorithm is based on the continuous wavelet transform with splines, which enables the selection of an optimum scale for reducing noise and mechanical interferences. The first step of the algorithm is a learning phase in which the first four heartbeats in the BCG are detected to define initial thresholds, search windows and interval limits. The learned parameters serve to identify the next heartbeat and are readapted after each heartbeat detected to follow the heart rate and signal-amplitude changes. To evaluate the agreement between results from the algorithm and the heart rate obtained from the ECG, a Bland–Altman plot has been used to compare them for seven seated subjects. The mean error obtained was −0.03 beats/min and the 95% confidence interval (±2 SD) was ±2.7 beats/min, which is within the accuracy limits recommended by the Association for the Advancement of Medical Instrumentation (AAMI) standard for heart rate meters.
- Is Part Of:
- Biomedical signal processing and control. Volume 27(2016)
- Journal:
- Biomedical signal processing and control
- Issue:
- Volume 27(2016)
- Issue Display:
- Volume 27, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 2016
- Issue Sort Value:
- 2016-0027-2016-0000
- Page Start:
- 96
- Page End:
- 102
- Publication Date:
- 2016-05
- Subjects:
- BCG -- Heart rate -- Wavelet transform
Signal processing -- Periodicals
Biomedical engineering -- Periodicals
Signal Processing, Computer-Assisted -- Periodicals
Image Processing, Computer-Assisted -- Periodicals
Biomedical Engineering -- Periodicals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17468094 ↗
http://www.elsevier.com/journals ↗
http://www.sciencedirect.com/science?_ob=PublicationURL&_tockey=%23TOC%2329675%232006%23999989998%23626449%23FLA%23&_cdi=29675&_pubType=J&_auth=y&_acct=C000045259&_version=1&_urlVersion=0&_userid=836873&md5=664b5cf9a57fc91971a17faf20c32ec1 ↗ - DOI:
- 10.1016/j.bspc.2016.02.002 ↗
- Languages:
- English
- ISSNs:
- 1746-8094
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2087.880400
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2193.xml