Use of the Reamer/Irrigator/Aspirator Decreases Carotid and Cranial Embolic Events in a Canine Model. (20th April 2016)
- Record Type:
- Journal Article
- Title:
- Use of the Reamer/Irrigator/Aspirator Decreases Carotid and Cranial Embolic Events in a Canine Model. (20th April 2016)
- Main Title:
- Use of the Reamer/Irrigator/Aspirator Decreases Carotid and Cranial Embolic Events in a Canine Model
- Authors:
- Miller, Anna N.
Deal, Dwight
Green, James
Houle, Timothy
Brown, William
Thore, Clara
Stump, David
Webb, Lawrence X. - Abstract:
- Abstract : Background: Approximately 2 million patients in the United States annually undergo total joint arthroplasty with reaming and placement of intramedullary nails, resulting in extravasation of bone marrow and fat into the circulatory system and potentially causing fat embolism syndrome. Acute and chronic changes in mental status documented after these procedures may be related to embolic events. The Reamer/Irrigator/Aspirator (RIA) device has been shown to decrease intramedullary pressure during reaming. We hypothesized that the use of the RIA in a canine model would reduce the number of microemboli detected in the carotid artery and brain compared with nailing either with or without reaming. Methods: Twenty-four large canines underwent unreamed nailing (UR), sequentially reamed nailing (SR), or RIA-reamed nailing (RIA) of bilateral femora (eight dogs per group). During reaming and nailing, the number and size of microemboli transiting the carotid artery were recorded. After euthanasia, the brain was harvested for immunostaining and measurement of microinfarction volumes. Results: Total embolic load passing through the carotid artery was 0.049 cc (UR), 0.045 cc (SR), and 0.013 cc (RIA). The number and size of microemboli in the UR and SR groups were similar; however, the RIA group had significantly fewer larger-sized (>200-μm) emboli (p = 0.03). Pathologic examination of the brain confirmed particulate emboli, and histologic analyses demonstrated upregulation ofAbstract : Background: Approximately 2 million patients in the United States annually undergo total joint arthroplasty with reaming and placement of intramedullary nails, resulting in extravasation of bone marrow and fat into the circulatory system and potentially causing fat embolism syndrome. Acute and chronic changes in mental status documented after these procedures may be related to embolic events. The Reamer/Irrigator/Aspirator (RIA) device has been shown to decrease intramedullary pressure during reaming. We hypothesized that the use of the RIA in a canine model would reduce the number of microemboli detected in the carotid artery and brain compared with nailing either with or without reaming. Methods: Twenty-four large canines underwent unreamed nailing (UR), sequentially reamed nailing (SR), or RIA-reamed nailing (RIA) of bilateral femora (eight dogs per group). During reaming and nailing, the number and size of microemboli transiting the carotid artery were recorded. After euthanasia, the brain was harvested for immunostaining and measurement of microinfarction volumes. Results: Total embolic load passing through the carotid artery was 0.049 cc (UR), 0.045 cc (SR), and 0.013 cc (RIA). The number and size of microemboli in the UR and SR groups were similar; however, the RIA group had significantly fewer larger-sized (>200-μm) emboli (p = 0.03). Pathologic examination of the brain confirmed particulate emboli, and histologic analyses demonstrated upregulation of stress-related proteins in all groups, with fewer emboli and less evidence of stress for RIA reaming. Conclusions: RIA reaming decreased microemboli compared with traditional reaming and unreamed nailing, suggesting that intramedullary pressure and heat are important variables. The documented embolic events and brain stress may help to explain subtle neurobehavioral symptoms commonly seen in patients after undergoing long-bone reaming procedures. Clinical Relevance: RIA reaming decreased cranial embolic events and may have an ameliorating effect on postoperative neurologic sequelae. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 98:Number 8(2016)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 98:Number 8(2016)
- Issue Display:
- Volume 98, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 98
- Issue:
- 8
- Issue Sort Value:
- 2016-0098-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-04-20
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.14.01176 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2751.xml