A single diamagnetic catalyCEST MRI contrast agent that detects cathepsin B enzyme activity by using a ratio of two CEST signals. (3rd December 2015)
- Record Type:
- Journal Article
- Title:
- A single diamagnetic catalyCEST MRI contrast agent that detects cathepsin B enzyme activity by using a ratio of two CEST signals. (3rd December 2015)
- Main Title:
- A single diamagnetic catalyCEST MRI contrast agent that detects cathepsin B enzyme activity by using a ratio of two CEST signals
- Authors:
- Hingorani, Dina V.
Montano, Luis A.
Randtke, Edward A.
Lee, Yeon Sun
Cárdenas‐Rodríguez, Julio
Pagel, Mark D. - Abstract:
- Abstract : CatalyCEST MRI can detect enzyme activity by monitoring the change in chemical exchange with water after a contrast agent is cleaved by an enzyme. Often these molecules use paramagnetic metals and are delivered with an additional non‐responsive reference molecule. To improve this approach for molecular imaging, a single diamagnetic agent with enzyme‐responsive and enzyme‐unresponsive CEST signals was synthesized and characterized. The CEST signal from the aryl amide disappeared after cleavage of a dipeptidyl ligand with cathepsin B, while a salicylic acid moiety was largely unresponsive to enzyme activity. The ratiometric comparison of the two CEST signals from the same agent allowed for concentration independent measurements of enzyme activity. The chemical exchange rate of the salicylic acid moiety was unchanged after enzyme catalysis, which further validated that this moiety was enzyme‐unresponsive. The temperature dependence of the chemical exchange rate of the salicylic acid moiety was non‐Arrhenius, suggesting a two‐step chemical exchange mechanism for salicylic acid. The good detection sensitivity at low saturation power facilitates clinical translation, along with the potentially low toxicity of a non‐metallic MRI contrast agent. The modular design of the agent constitutes a platform technology that expands the variety of agents that may be employed by catalyCEST MRI for molecular imaging. Copyright © 2015 John Wiley & Sons, Ltd. Abstract : A catalyCESTAbstract : CatalyCEST MRI can detect enzyme activity by monitoring the change in chemical exchange with water after a contrast agent is cleaved by an enzyme. Often these molecules use paramagnetic metals and are delivered with an additional non‐responsive reference molecule. To improve this approach for molecular imaging, a single diamagnetic agent with enzyme‐responsive and enzyme‐unresponsive CEST signals was synthesized and characterized. The CEST signal from the aryl amide disappeared after cleavage of a dipeptidyl ligand with cathepsin B, while a salicylic acid moiety was largely unresponsive to enzyme activity. The ratiometric comparison of the two CEST signals from the same agent allowed for concentration independent measurements of enzyme activity. The chemical exchange rate of the salicylic acid moiety was unchanged after enzyme catalysis, which further validated that this moiety was enzyme‐unresponsive. The temperature dependence of the chemical exchange rate of the salicylic acid moiety was non‐Arrhenius, suggesting a two‐step chemical exchange mechanism for salicylic acid. The good detection sensitivity at low saturation power facilitates clinical translation, along with the potentially low toxicity of a non‐metallic MRI contrast agent. The modular design of the agent constitutes a platform technology that expands the variety of agents that may be employed by catalyCEST MRI for molecular imaging. Copyright © 2015 John Wiley & Sons, Ltd. Abstract : A catalyCEST MRI contrast agent with enzyme‐responsive and enzyme‐ unresponsive CEST signals was developed to detect cathepsin B activity. The ratio of CEST signals was used to improve the detection of cathepsin B activity. The modular design of the agent is a platform technology that can improve catalyCEST MRI for molecular imaging. … (more)
- Is Part Of:
- Contrast media & molecular imaging. Volume 11:Number 2(2016:Mar./Apr.)
- Journal:
- Contrast media & molecular imaging
- Issue:
- Volume 11:Number 2(2016:Mar./Apr.)
- Issue Display:
- Volume 11, Issue 2 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 2
- Issue Sort Value:
- 2016-0011-0002-0000
- Page Start:
- 130
- Page End:
- 138
- Publication Date:
- 2015-12-03
- Subjects:
- CEST MRI -- enzyme activity -- cathepsin B -- ratiometric analysis
Diagnostic imaging -- Periodicals
Magnetic resonance imaging -- Periodicals
Contrast media (Diagnostic imaging) -- Periodicals
Contrast Media -- Periodicals
Diagnostic Imaging -- Periodicals
Substances de contraste -- Périodiques
Diagnostics moléculaires -- Périodiques
Imagerie médicale
Substance de contraste
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.0754 - Journal URLs:
- https://onlinelibrary.wiley.com/journal/15554317 ↗
https://www.hindawi.com/journals/cmmi/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cmmi.1672 ↗
- Languages:
- English
- ISSNs:
- 1555-4309
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3426.351450
British Library HMNTS - ELD Digital store - Ingest File:
- 1817.xml