Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty: Data from a Prospective, Randomized Controlled Study. (20th April 2016)
- Record Type:
- Journal Article
- Title:
- Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty: Data from a Prospective, Randomized Controlled Study. (20th April 2016)
- Main Title:
- Improved Accuracy of Component Positioning with Robotic-Assisted Unicompartmental Knee Arthroplasty
- Authors:
- Bell, Stuart W.
Anthony, Iain
Jones, Bryn
MacLean, Angus
Rowe, Philip
Blyth, Mark - Abstract:
- Abstract : Background: Higher revision rates have been reported in patients who have undergone unicompartmental knee arthroplasty compared with patients who have undergone total knee arthroplasty, with poor component positioning identified as a factor in implant failure. A robotic-assisted surgical procedure has been proposed as a method of improving the accuracy of component implantation in arthroplasty. The aim of this prospective, randomized, single-blinded, controlled trial was to evaluate the accuracy of component positioning in unicompartmental knee arthroplasty comparing robotic-assisted and conventional implantation techniques. Methods: One hundred and thirty-nine patients were randomly assigned to treatment with either a robotic-assisted surgical procedure using the MAKO Robotic Interactive Orthopaedic Arm (RIO) system or a conventional surgical procedure using the Oxford Phase-3 unicompartmental knee replacement with traditional instrumentation. A postoperative computed tomographic scan was performed at three months to assess the accuracy of the axial, coronal, and sagittal component positioning. Results: Data were available for 120 patients, sixty-two who had undergone robotic-assisted unicompartmental knee arthroplasty and fifty-eight who had undergone conventional unicompartmental knee arthroplasty. Intraobserver agreement was good for all measured component parameters. The accuracy of component positioning was improved with the use of the robotic-assistedAbstract : Background: Higher revision rates have been reported in patients who have undergone unicompartmental knee arthroplasty compared with patients who have undergone total knee arthroplasty, with poor component positioning identified as a factor in implant failure. A robotic-assisted surgical procedure has been proposed as a method of improving the accuracy of component implantation in arthroplasty. The aim of this prospective, randomized, single-blinded, controlled trial was to evaluate the accuracy of component positioning in unicompartmental knee arthroplasty comparing robotic-assisted and conventional implantation techniques. Methods: One hundred and thirty-nine patients were randomly assigned to treatment with either a robotic-assisted surgical procedure using the MAKO Robotic Interactive Orthopaedic Arm (RIO) system or a conventional surgical procedure using the Oxford Phase-3 unicompartmental knee replacement with traditional instrumentation. A postoperative computed tomographic scan was performed at three months to assess the accuracy of the axial, coronal, and sagittal component positioning. Results: Data were available for 120 patients, sixty-two who had undergone robotic-assisted unicompartmental knee arthroplasty and fifty-eight who had undergone conventional unicompartmental knee arthroplasty. Intraobserver agreement was good for all measured component parameters. The accuracy of component positioning was improved with the use of the robotic-assisted surgical procedure, with lower root mean square errors and significantly lower median errors in all component parameters (p < 0.01). The proportion of patients with component implantation within 2° of the target position was significantly greater in the group who underwent robotic-assisted unicompartmental knee arthroplasty compared with the group who underwent conventional unicompartmental knee arthroscopy with regard to the femoral component sagittal position (57% compared with 26%, p = 0.0008), femoral component coronal position (70% compared with 28%, p = 0.0001), femoral component axial position (53% compared with 31%, p = 0.0163), tibial component sagittal position (80% compared with 22%, p = 0.0001), and tibial component axial position (48% compared with 19%, p = 0.0009). Conclusions: Robotic-assisted surgical procedures with the use of the MAKO RIO lead to improved accuracy of implant positioning compared with conventional unicompartmental knee arthroplasty surgical techniques. Level of Evidence: TherapeuticLevel I . See Instructions for Authors for a complete description of levels of evidence. … (more)
- Is Part Of:
- Journal of bone and joint surgery. Volume 98:Number 8(2016)
- Journal:
- Journal of bone and joint surgery
- Issue:
- Volume 98:Number 8(2016)
- Issue Display:
- Volume 98, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 98
- Issue:
- 8
- Issue Sort Value:
- 2016-0098-0008-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-04-20
- Subjects:
- Bones -- Surgery -- Periodicals
Joints -- Surgery -- Periodicals
Orthopedics -- Periodicals
Orthopedics
General Surgery
Bone Diseases
Joint Diseases
Bones -- Surgery
Joints -- Surgery
Orthopedics
Bot (anatomie)
Gewrichten
Chirurgie (geneeskunde)
Periodicals
Electronic journals
Periodicals
617.47005 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/00219355 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00219355 ↗
http://www.ejbjs.org/contents-by-date.0.dtl ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com/pages/default.aspx ↗ - DOI:
- 10.2106/JBJS.15.00664 ↗
- Languages:
- English
- ISSNs:
- 0021-9355
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.250000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2751.xml