Development of the A-DIVA Scale: A Clinical Predictive Scale to Identify Difficult Intravenous Access in Adult Patients Based on Clinical Observations. Issue 16 (April 2016)
- Record Type:
- Journal Article
- Title:
- Development of the A-DIVA Scale: A Clinical Predictive Scale to Identify Difficult Intravenous Access in Adult Patients Based on Clinical Observations. Issue 16 (April 2016)
- Main Title:
- Development of the A-DIVA Scale
- Authors:
- Loon, Fredericus H. J. van
Puijn, Lisette A. P. M.
Houterman, Saskia
Bouwman, Arthur R. A. - Other Names:
- Mansur. Ashham section editor.
- Abstract:
- Abstract : Abstract: Placement of a peripheral intravenous catheter is a routine procedure in clinical practice, but failure of intravenous cannulation regularly occurs. An accurate and reliable predictive scale for difficult venous access creates the possibility to use other techniques in an earlier time frame. We aimed to develop a predictive scale to identify adult patients with a difficult intravenous access prospectively: the A-DIVA scale. This prospective, observational, cross-sectional cohort study was conducted between January 2014 and January 2015, and performed at the department of anesthesiology of the Catharina Hospital (Eindhoven, The Netherlands). Patients 18 years or older were eligible if scheduled for any surgical procedure, regardless ASA classification, demographics, and medical history. Experienced and certified anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access. Cannulation was performed regarding standards for care. A failed peripheral intravenous cannulation on the first attempt was the outcome of interest. A population-based sample of 1063 patients was included. Failure of intravenous cannulation was observed in 182/1063 patients (17%). Five variables were associated with a failed first attempt of peripheral intravenous cannulation: palpability of the target vein (OR = 4.94, 95% CI [2.85–8.56]; P < 0.001), visibility of the target vein (OR = 3.63, 95% CI [2.09–6.32]; P < 0.001), a history of difficultAbstract : Abstract: Placement of a peripheral intravenous catheter is a routine procedure in clinical practice, but failure of intravenous cannulation regularly occurs. An accurate and reliable predictive scale for difficult venous access creates the possibility to use other techniques in an earlier time frame. We aimed to develop a predictive scale to identify adult patients with a difficult intravenous access prospectively: the A-DIVA scale. This prospective, observational, cross-sectional cohort study was conducted between January 2014 and January 2015, and performed at the department of anesthesiology of the Catharina Hospital (Eindhoven, The Netherlands). Patients 18 years or older were eligible if scheduled for any surgical procedure, regardless ASA classification, demographics, and medical history. Experienced and certified anesthesiologists and nurse anesthetists routinely obtained peripheral intravenous access. Cannulation was performed regarding standards for care. A failed peripheral intravenous cannulation on the first attempt was the outcome of interest. A population-based sample of 1063 patients was included. Failure of intravenous cannulation was observed in 182/1063 patients (17%). Five variables were associated with a failed first attempt of peripheral intravenous cannulation: palpability of the target vein (OR = 4.94, 95% CI [2.85–8.56]; P < 0.001), visibility of the target vein (OR = 3.63, 95% CI [2.09–6.32]; P < 0.001), a history of difficult peripheral intravenous cannulation (OR = 3.86, 95% CI [2.39–6.25]; P < 0.001), an unplanned indication for surgery (OR = 4.86, 95% CI [2.92–8.07]; P < 0.001), and the vein diameter of at most 2 millimeters (OR = 3.37, 95% CI [2.12–5.36]; P < 0.001). The scoring system was applied in 3 risk groups: 36/788 patients (5%) suffered from a failed first attempt in the low-risk group (A-DIVA score 0 or 1), whereas the medium (A-DIVA score 2 or 3) and high-risk group (A-DIVA score 4 plus), included 72/195 (37%) and 74/80 (93%) patients with a failed first attempt of inserting a peripheral intravenous catheter, respectively. The additive 5-variable A-DIVA scale is a reliable predictive rule that implies the probability to identify patients with a difficult intravenous access prospectively. Dutch Trial Register (ref: 4595). … (more)
- Is Part Of:
- Medicine. Volume 95:Issue 16(2016)
- Journal:
- Medicine
- Issue:
- Volume 95:Issue 16(2016)
- Issue Display:
- Volume 95, Issue 16 (2016)
- Year:
- 2016
- Volume:
- 95
- Issue:
- 16
- Issue Sort Value:
- 2016-0095-0016-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-04
- Subjects:
- Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000003428 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1289.xml