Diurnal variation of anterior scleral and conjunctival thickness. (1st March 2016)
- Record Type:
- Journal Article
- Title:
- Diurnal variation of anterior scleral and conjunctival thickness. (1st March 2016)
- Main Title:
- Diurnal variation of anterior scleral and conjunctival thickness
- Authors:
- Read, Scott A.
Alonso‐Caneiro, David
Free, Kelly A.
Labuc‐Spoors, Elspeth
Leigh, Jaron K.
Quirk, Charlotte J.
Yang, Zoe Y.‐L.
Vincent, Stephen J. - Other Names:
- Thompson Benjamin guestEditor.
Read Scott A. guestEditor.
Dumoulin Serge O. guestEditor.
Elsner Ann E. guestEditor.
Porter Jason guestEditor.
Roorda Austin guestEditor. - Abstract:
- Abstract: Purpose: To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24‐h period. Methods: Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction −0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS‐OCT) at seven measurement sessions over a 24‐h period. The thickness of the temporal anterior sclera and conjunctiva were determined at six locations (each separated by 0.5 mm) at varying distances from the scleral spur (SS) for each subject at each measurement session. Results: Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24‐h period (both p < 0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the SS location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions: This study provides the first evidence of diurnal variations occurring in the thickness ofAbstract: Purpose: To examine whether anterior scleral and conjunctival thickness undergoes significant diurnal variation over a 24‐h period. Methods: Nineteen healthy young adults (mean age 22 ± 2 years) with minimal refractive error (mean spherical equivalent refraction −0.08 ± 0.39 D), had measures of anterior scleral and conjunctival thickness collected using anterior segment optical coherence tomography (AS‐OCT) at seven measurement sessions over a 24‐h period. The thickness of the temporal anterior sclera and conjunctiva were determined at six locations (each separated by 0.5 mm) at varying distances from the scleral spur (SS) for each subject at each measurement session. Results: Both the anterior sclera and conjunctiva were found to undergo significant diurnal variations in thickness over a 24‐h period (both p < 0.01). The sclera and conjunctiva exhibited a similar pattern of diurnal change, with a small magnitude thinning observed close to midday, and a larger magnitude thickening observed in the early morning immediately after waking. The amplitude of diurnal thickness change was larger in the conjunctiva (mean amplitude 69 ± 29 μm) compared to the sclera (21 ± 8 μm). The conjunctiva exhibited its smallest magnitude of change at the SS location (mean amplitude 56 ± 17 μm) whereas the sclera exhibited its largest magnitude of change at this location (52 ± 21 μm). Conclusions: This study provides the first evidence of diurnal variations occurring in the thickness of the anterior sclera and conjunctiva. Studies requiring precise measures of these anatomical layers should therefore take time of day into consideration. The majority of the observed changes occurred in the early morning immediately after waking and were of larger magnitude in the conjunctiva compared to the sclera. Thickness changes at other times of the day were of smaller magnitude and generally not statistically significant. … (more)
- Is Part Of:
- Ophthalmic and physiological optics. Volume 36:Number 3(2016:May)
- Journal:
- Ophthalmic and physiological optics
- Issue:
- Volume 36:Number 3(2016:May)
- Issue Display:
- Volume 36, Issue 3 (2016)
- Year:
- 2016
- Volume:
- 36
- Issue:
- 3
- Issue Sort Value:
- 2016-0036-0003-0000
- Page Start:
- 279
- Page End:
- 289
- Publication Date:
- 2016-03-01
- Subjects:
- anterior segment -- conjunctiva -- diurnal -- optical coherence tomography -- sclera
Ophthalmology -- Periodicals
Physiological optics -- Periodicals
Optometry -- Periodicals
Optics -- Periodicals
Vision -- Periodicals
617.75 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0275-5408&site=1 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/opo.12288 ↗
- Languages:
- English
- ISSNs:
- 0275-5408
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.870000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1349.xml