Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method. Issue 4 (April 2016)
- Record Type:
- Journal Article
- Title:
- Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method. Issue 4 (April 2016)
- Main Title:
- Temporal resolution measurement of 128-slice dual source and 320-row area detector computed tomography scanners in helical acquisition mode using the impulse method
- Authors:
- Hara, Takanori
Urikura, Atsushi
Ichikawa, Katsuhiro
Hoshino, Takashi
Nishimaru, Eiji
Niwa, Shinji - Abstract:
- Abstract : Highlights: Temporal resolution (TR) of modern CT scanners was analysed using an impulse method. Scan combinations of pitch factor ( P ) and gantry rotation time ( R ) were assessed. For 320-row ADCT, TR ≈ R (with P < 1.0), whereas TR ≈ 0.5 R (with P > 1.0). For 128-slice DSCT, TR improved with a shorter R and greater P. TR of helical acquisition modes were dependent on not only R but also P . Abstract: Purpose: To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. Methods: To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor ( P ) and gantry rotation time ( R ). Results: The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of <1.0 was almost equal to the gantry rotation time, whereas with pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 ( R / P = 0.285/1.5) and 0.074 s ( R / P = 0.285/3.2), and the maximum TR values of the 64 × 0.5- and 160 × 0.5-mmAbstract : Highlights: Temporal resolution (TR) of modern CT scanners was analysed using an impulse method. Scan combinations of pitch factor ( P ) and gantry rotation time ( R ) were assessed. For 320-row ADCT, TR ≈ R (with P < 1.0), whereas TR ≈ 0.5 R (with P > 1.0). For 128-slice DSCT, TR improved with a shorter R and greater P. TR of helical acquisition modes were dependent on not only R but also P . Abstract: Purpose: To analyse the temporal resolution (TR) of modern computed tomography (CT) scanners using the impulse method, and assess the actual maximum TR at respective helical acquisition modes. Methods: To assess the actual TR of helical acquisition modes of a 128-slice dual source CT (DSCT) scanner and a 320-row area detector CT (ADCT) scanner, we assessed the TRs of various acquisition combinations of a pitch factor ( P ) and gantry rotation time ( R ). Results: The TR of the helical acquisition modes for the 128-slice DSCT scanner continuously improved with a shorter gantry rotation time and greater pitch factor. However, for the 320-row ADCT scanner, the TR with a pitch factor of <1.0 was almost equal to the gantry rotation time, whereas with pitch factor of >1.0, it was approximately one half of the gantry rotation time. The maximum TR values of single- and dual-source helical acquisition modes for the 128-slice DSCT scanner were 0.138 ( R / P = 0.285/1.5) and 0.074 s ( R / P = 0.285/3.2), and the maximum TR values of the 64 × 0.5- and 160 × 0.5-mm detector configurations of the helical acquisition modes for the 320-row ADCT scanner were 0.120 ( R / P = 0.275/1.375) and 0.195 s ( R / P = 0.3/0.6), respectively. Conclusion: Because the TR of a CT scanner is not accurately depicted in the specifications of the individual scanner, appropriate acquisition conditions should be determined based on the actual TR measurement. … (more)
- Is Part Of:
- Physica medica. Volume 32:Issue 4(2016)
- Journal:
- Physica medica
- Issue:
- Volume 32:Issue 4(2016)
- Issue Display:
- Volume 32, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 32
- Issue:
- 4
- Issue Sort Value:
- 2016-0032-0004-0000
- Page Start:
- 625
- Page End:
- 630
- Publication Date:
- 2016-04
- Subjects:
- Temporal resolution -- Helical acquisition mode -- Gantry rotation time -- Pitch factor
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2016.02.015 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2592.xml