Determination of the least amount of iodine load required for the detection of pancreatic adenocarcinoma at 80-kVp CT. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Determination of the least amount of iodine load required for the detection of pancreatic adenocarcinoma at 80-kVp CT. Issue 5 (May 2016)
- Main Title:
- Determination of the least amount of iodine load required for the detection of pancreatic adenocarcinoma at 80-kVp CT
- Authors:
- Noda, Yoshifumi
Goshima, Satoshi
Miyoshi, Toshiharu
Watanabe, Haruo
Kawada, Hiroshi
Kawai, Nobuyuki
Koyasu, Hiromi
Kanematsu, Masayuki
Matsuo, Masayuki
T Bae, Kyongtae - Abstract:
- Abstract: Purpose: To determine the iodine load per body weight (ILPBW) that is minimally required for the detection of pancreatic adenocarcinoma for 80 kVp CT imaging. Material and methods: Institutional review board approval and written informed consent were obtained. Fifty-seven consecutive patients with histopathologically-proven pancreatic adenocarcinoma were assigned to three groups at random according to iodine load (0.5, 0.4, and 0.3 gI/kg) and underwent CT at 80 kVp. Enhancement of the pancreas and visualization of the tumor were assessed during the pancreatic parenchymal-phase and compared among the three groups. The relationship between the iodine load and tumor conspicuity was also analyzed. Results: The mean CT number of the pancreas (HUpancreas ) was higher in the 0.5 gI/kg group (158.8HU) than in the 0.4 (121.7HU) and 0.3 (106.6HU) gI/kg groups ( P < 0.05). Tumor-to-pancreas contrast (HUtumor-to-pancreas ) was also higher in 0.5 gI/kg group (88.9HU) than in 0.4 (62.2HU) and 0.3 (54.5HU) gI/kg groups ( P < 0.05). Linear regression between HUpancreas or HUtumor-to-pancreas and ILPBW were expressed as HUpancreas = 23.3 + 263.9 × ILPBW ( r = 0.74, P < 0.0001) and HUtumor-to-pancreas = −1.24 + 174.3 × ILPBW ( r = 0.56, P < 0.0001), respectively. The iodine load estimated to achieve an acceptable HUpancreas (>100HU) and HUtumor-to-pancreas (>50HU) were 0.29 and 0.30 gI/kg, respectively. Conclusion: An iodine load of 0.3 gI/kg was the least amount requiredAbstract: Purpose: To determine the iodine load per body weight (ILPBW) that is minimally required for the detection of pancreatic adenocarcinoma for 80 kVp CT imaging. Material and methods: Institutional review board approval and written informed consent were obtained. Fifty-seven consecutive patients with histopathologically-proven pancreatic adenocarcinoma were assigned to three groups at random according to iodine load (0.5, 0.4, and 0.3 gI/kg) and underwent CT at 80 kVp. Enhancement of the pancreas and visualization of the tumor were assessed during the pancreatic parenchymal-phase and compared among the three groups. The relationship between the iodine load and tumor conspicuity was also analyzed. Results: The mean CT number of the pancreas (HUpancreas ) was higher in the 0.5 gI/kg group (158.8HU) than in the 0.4 (121.7HU) and 0.3 (106.6HU) gI/kg groups ( P < 0.05). Tumor-to-pancreas contrast (HUtumor-to-pancreas ) was also higher in 0.5 gI/kg group (88.9HU) than in 0.4 (62.2HU) and 0.3 (54.5HU) gI/kg groups ( P < 0.05). Linear regression between HUpancreas or HUtumor-to-pancreas and ILPBW were expressed as HUpancreas = 23.3 + 263.9 × ILPBW ( r = 0.74, P < 0.0001) and HUtumor-to-pancreas = −1.24 + 174.3 × ILPBW ( r = 0.56, P < 0.0001), respectively. The iodine load estimated to achieve an acceptable HUpancreas (>100HU) and HUtumor-to-pancreas (>50HU) were 0.29 and 0.30 gI/kg, respectively. Conclusion: An iodine load of 0.3 gI/kg was the least amount required for the detection of pancreatic adenocarcinoma at 80 kVp CT. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 5(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 5(2016)
- Issue Display:
- Volume 85, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2016-0085-0005-0000
- Page Start:
- 901
- Page End:
- 905
- Publication Date:
- 2016-05
- Subjects:
- Pancreas -- CT -- Pancreatic adenocarcinoma -- Contrast -- 80 kVp
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.02.014 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1303.xml