Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences. Issue 5 (May 2016)
- Record Type:
- Journal Article
- Title:
- Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences. Issue 5 (May 2016)
- Main Title:
- Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences
- Authors:
- Inoue, Katsuhiro
Maeda, Masayuki
Umino, Maki
Takase, Shinichi
Yamahata, Tsunehiro
Sakuma, Hajime - Abstract:
- Abstract: Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field-echo (TFE) black-blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36–83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1-TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1-TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1- TFEBB MRI than on 3D T1-TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1-TSEBB MRI. Conclusions: 3D T1-TSEBB MRI was superior to 3D T1-TFEBB MRI forAbstract: Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field-echo (TFE) black-blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36–83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1-TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1-TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1- TFEBB MRI than on 3D T1-TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1-TSEBB MRI. Conclusions: 3D T1-TSEBB MRI was superior to 3D T1-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1-TSEBB MRI. … (more)
- Is Part Of:
- European journal of radiology. Volume 85:Issue 5(2016)
- Journal:
- European journal of radiology
- Issue:
- Volume 85:Issue 5(2016)
- Issue Display:
- Volume 85, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 85
- Issue:
- 5
- Issue Sort Value:
- 2016-0085-0005-0000
- Page Start:
- 1035
- Page End:
- 1039
- Publication Date:
- 2016-05
- Subjects:
- Carotid plaque -- Magnetic resonance imaging -- Black blood -- 3D imaging
Medical radiology -- Periodicals
Radiology -- Periodicals
Radiologie médicale -- Périodiques
Medical radiology
Periodicals
616.075705 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0720048X ↗
http://www.elsevier.com/homepage/elecserv.htt ↗
http://www.clinicalkey.com/dura/browse/journalIssue/0720048X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/0720048X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ejrad.2016.03.007 ↗
- Languages:
- English
- ISSNs:
- 0720-048X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.738050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 1303.xml