Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study. Issue 5 (18th June 2015)
- Record Type:
- Journal Article
- Title:
- Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study. Issue 5 (18th June 2015)
- Main Title:
- Influence of implant angulation and cyclic dislodging on the retentive force of two different overdenture attachments – an in vitro study
- Authors:
- Srinivasan, Murali
Schimmel, Martin
Badoud, Isabelle
Ammann, Patrick
Herrmann, François R.
Müller, Frauke - Abstract:
- Abstract: Objective: This in vitro study evaluated the influence of implant angulations on the retentive behavior of two overdenture attachments during cyclic dislodging. Methods: Models simulating a two‐implant overdenture situation were fabricated. They were divided into five groups based on their simulated implant angulations (Groups: 1 = 0°; 2 = 20°; 3 = 30°; 4 = 40°; and 5 = 60°; n = 90). Each group was further divided into two subgroups based on its attachment system (control attachment: LOCATOR ® ; test attachment: SFI‐Anchor ® ) except for group 5 which had no LOCATOR ® group. All models underwent 10, 000 insertion–removal cycles in a wet environment. Mean retentive forces were recorded. ANOVA and linear regression models were used for statistical analyses, and the level of significance was at P < 0.05. Results: The ANOVA model revealed an effect of dislodging cycles for both attachments ( P = 0.0070). The linear regression model with repeated measures revealed a significant effect of angulation within the LOCATOR ® groups (0° vs. 20°: P < 0.0001; 0° vs. 30°: P < 0.0001; 0° vs. 40°: P < 0.0001), but was insignificant within the SFI‐Anchor ® groups (0° vs. 20°: P = 0.544; 0° vs. 30°: P = 0.134; 0° vs. 40°: P = 0.254; 0° vs. 60°: P = 0.979). It further revealed a significant increase in the retentive force between the LOCATOR ® and the SFI‐Anchor ® (20°: P = 0.041; 30°: P < 0.0001; 40°: P < 0.0001), although there was no significantAbstract: Objective: This in vitro study evaluated the influence of implant angulations on the retentive behavior of two overdenture attachments during cyclic dislodging. Methods: Models simulating a two‐implant overdenture situation were fabricated. They were divided into five groups based on their simulated implant angulations (Groups: 1 = 0°; 2 = 20°; 3 = 30°; 4 = 40°; and 5 = 60°; n = 90). Each group was further divided into two subgroups based on its attachment system (control attachment: LOCATOR ® ; test attachment: SFI‐Anchor ® ) except for group 5 which had no LOCATOR ® group. All models underwent 10, 000 insertion–removal cycles in a wet environment. Mean retentive forces were recorded. ANOVA and linear regression models were used for statistical analyses, and the level of significance was at P < 0.05. Results: The ANOVA model revealed an effect of dislodging cycles for both attachments ( P = 0.0070). The linear regression model with repeated measures revealed a significant effect of angulation within the LOCATOR ® groups (0° vs. 20°: P < 0.0001; 0° vs. 30°: P < 0.0001; 0° vs. 40°: P < 0.0001), but was insignificant within the SFI‐Anchor ® groups (0° vs. 20°: P = 0.544; 0° vs. 30°: P = 0.134; 0° vs. 40°: P = 0.254; 0° vs. 60°: P = 0.979). It further revealed a significant increase in the retentive force between the LOCATOR ® and the SFI‐Anchor ® (20°: P = 0.041; 30°: P < 0.0001; 40°: P < 0.0001), although there was no significant difference between the attachments at 0° ( P = 0.623). Conclusions: This study confirms that the retentive behavior of SFI‐Anchor ® is not influenced by implant axial inclination even at angulations of up to 60°. The SFI‐Anchor ® may therefore be particularly indicated for clinical situations with marked implant axial discrepancies. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 27:Issue 5(2016)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 27:Issue 5(2016)
- Issue Display:
- Volume 27, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2016-0027-0005-0000
- Page Start:
- 604
- Page End:
- 611
- Publication Date:
- 2015-06-18
- Subjects:
- artificial saliva -- dislodging cycles -- implant overdentures -- in vitro testing -- LOCATOR ® -- overdentures -- retentive force -- SFI‐Anchor®
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12643 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 338.xml