Detection of peri‐implant bone defects with different radiographic techniques – a human cadaver study. Issue 5 (7th June 2015)
- Record Type:
- Journal Article
- Title:
- Detection of peri‐implant bone defects with different radiographic techniques – a human cadaver study. Issue 5 (7th June 2015)
- Main Title:
- Detection of peri‐implant bone defects with different radiographic techniques – a human cadaver study
- Authors:
- Kühl, Sebastian
Zürcher, Silvia
Zitzmann, Nicola U.
Filippi, Andreas
Payer, Michael
Dagassan‐Berndt, Dorothea - Abstract:
- Abstract: Objectives: Two‐ and three‐dimensional radiographic techniques are available to determine peri‐implantitis‐related bone loss around dental implants. Purpose: To compare the performance of detecting different peri‐implant bone defects in intraoral radiography (IR), panoramic radiography (PR), Cone Beam Computer Tomography (CBCT) and Computer Tomography (CT). Material and methods: Six implants were inserted under ideal conditions into the lower jaw of an edentulous human cadaver. IR, PR, CBCT and CT were performed. Two‐wall, three‐wall and four‐wall defects with 1 mm depth were artificially created around two of the implants (one anterior and one posterior), and radiographies were repeated. The identical set‐up was used for 3‐mm‐deep bone defects. All images were presented to seven observers. Sensitivity (SN) and specificity (SP) were determined for each modality, defect type and depths, and likelihood ratios were calculated. Results: The highest sensitivity was found with IR and CBCT for 1 mm (0.67; 0.68) and 3‐mm defects (0.81; 0.79). The highest specificity was found with IR for both defect depths (0.51). The best classification of defect type revealed PR for both 1‐mm and 3‐mm‐deep defects. Both likelihood ratios (LR+ and LR−) were best for IR with 1‐mm (1.37 and 0.65) and with 3‐mm defects (1.65 and 0.37). Conclusions: IR should still be recommended as favourable method evaluating bone loss around dental implants, while CT demonstrated the lowest performance inAbstract: Objectives: Two‐ and three‐dimensional radiographic techniques are available to determine peri‐implantitis‐related bone loss around dental implants. Purpose: To compare the performance of detecting different peri‐implant bone defects in intraoral radiography (IR), panoramic radiography (PR), Cone Beam Computer Tomography (CBCT) and Computer Tomography (CT). Material and methods: Six implants were inserted under ideal conditions into the lower jaw of an edentulous human cadaver. IR, PR, CBCT and CT were performed. Two‐wall, three‐wall and four‐wall defects with 1 mm depth were artificially created around two of the implants (one anterior and one posterior), and radiographies were repeated. The identical set‐up was used for 3‐mm‐deep bone defects. All images were presented to seven observers. Sensitivity (SN) and specificity (SP) were determined for each modality, defect type and depths, and likelihood ratios were calculated. Results: The highest sensitivity was found with IR and CBCT for 1 mm (0.67; 0.68) and 3‐mm defects (0.81; 0.79). The highest specificity was found with IR for both defect depths (0.51). The best classification of defect type revealed PR for both 1‐mm and 3‐mm‐deep defects. Both likelihood ratios (LR+ and LR−) were best for IR with 1‐mm (1.37 and 0.65) and with 3‐mm defects (1.65 and 0.37). Conclusions: IR should still be recommended as favourable method evaluating bone loss around dental implants, while CT demonstrated the lowest performance in detecting peri‐implant bone defects. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 27:Issue 5(2016)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 27:Issue 5(2016)
- Issue Display:
- Volume 27, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 27
- Issue:
- 5
- Issue Sort Value:
- 2016-0027-0005-0000
- Page Start:
- 529
- Page End:
- 534
- Publication Date:
- 2015-06-07
- Subjects:
- clinical assessment -- CT Imaging -- diagnosis -- imaging -- radiology
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.12619 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 338.xml