Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio. (18th November 2015)
- Record Type:
- Journal Article
- Title:
- Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio. (18th November 2015)
- Main Title:
- Determination of sperm concentration using flow cytometry with simultaneous analysis of sperm plasma membrane integrity in zebrafish Danio rerio
- Authors:
- Yang, Huiping
Daly, Jonathan
Tiersch, Terrence R. - Abstract:
- Abstract: Control of sperm concentration is required to ensure consistent and reproducible results for cryopreservation and in vitro fertilization protocols. Determination of sperm concentration is traditionally performed with a counting chamber (e.g., hemocytometer), or more recently with a spectrophotometer. For small‐sized biomedical model fishes, the availability of sperm sample is limited to microliters, so it is desirable to develop fast and accurate approaches for concentration determination that also minimize sample use. In this study, a new approach was developed for sperm concentration determination using a flow cytometer (Accuri C6, BD Biosciences, San Jose, CA) with simultaneous measurement of sperm membrane integrity after fluorescent staining with SYBR ® −14 and propidium iodide (PI) in sperm from Zebrafish Danio rerio . The goal was to develop a protocol for simultaneous determination of sperm quality and quantity by flow cytometry. The objectives were to (1) determine the effects of sample volume (250 and 500 µl) and analysis volume (10 and 50 µl) on the accuracy of particle counting using standard volumetric validation beads; (2) identify the effective range of sperm concentrations that flow cytometry can measure; (3) test the precision and reproducibility of the sperm concentration measurements; and (4) verify the flow cytometry approach by comparison with measurement with a hemocytometer and a microspectrophotometer. Sample volumes of 250 and 500 µl andAbstract: Control of sperm concentration is required to ensure consistent and reproducible results for cryopreservation and in vitro fertilization protocols. Determination of sperm concentration is traditionally performed with a counting chamber (e.g., hemocytometer), or more recently with a spectrophotometer. For small‐sized biomedical model fishes, the availability of sperm sample is limited to microliters, so it is desirable to develop fast and accurate approaches for concentration determination that also minimize sample use. In this study, a new approach was developed for sperm concentration determination using a flow cytometer (Accuri C6, BD Biosciences, San Jose, CA) with simultaneous measurement of sperm membrane integrity after fluorescent staining with SYBR ® −14 and propidium iodide (PI) in sperm from Zebrafish Danio rerio . The goal was to develop a protocol for simultaneous determination of sperm quality and quantity by flow cytometry. The objectives were to (1) determine the effects of sample volume (250 and 500 µl) and analysis volume (10 and 50 µl) on the accuracy of particle counting using standard volumetric validation beads; (2) identify the effective range of sperm concentrations that flow cytometry can measure; (3) test the precision and reproducibility of the sperm concentration measurements; and (4) verify the flow cytometry approach by comparison with measurement with a hemocytometer and a microspectrophotometer. Sample volumes of 250 and 500 µl and analysis volumes of 10 and 50 µl did not affect bead count with the factory‐set flow rates of "medium" or "fast, " and the precision and accuracy was retained across a concentration range of 1 × 10 3 −1 × 10 7 cells/ml. The approach developed in this study was comparable to traditional methodologies such as hemocytometer or microspectrophotometer. This study provides an efficient, accurate, and rapid method for determination of sperm concentration using flow cytometry while providing simultaneous assessment of sperm membrane integrity. Such approaches can reduce the time needed for quantity assessment and maximize the use of valuable sperm samples. © 2015 International Society for Advancement of Cytometry … (more)
- Is Part Of:
- Cytometry. Volume 89:Number 4(2016)
- Journal:
- Cytometry
- Issue:
- Volume 89:Number 4(2016)
- Issue Display:
- Volume 89, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 89
- Issue:
- 4
- Issue Sort Value:
- 2016-0089-0004-0000
- Page Start:
- 350
- Page End:
- 356
- Publication Date:
- 2015-11-18
- Subjects:
- zebrafish -- flow cytometry -- sperm concentration -- membrane integrity
Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.22796 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 1724.xml