Effect of partial-thickness tear on loading capacities of the supraspinatus tendon: a finite element analysis. Issue 8 (10th June 2016)
- Record Type:
- Journal Article
- Title:
- Effect of partial-thickness tear on loading capacities of the supraspinatus tendon: a finite element analysis. Issue 8 (10th June 2016)
- Main Title:
- Effect of partial-thickness tear on loading capacities of the supraspinatus tendon: a finite element analysis
- Authors:
- Engelhardt, Christoph
Ingram, David
Müllhaupt, Philippe
Farron, Alain
Becce, Fabio
Pioletti, Dominique
Terrier, Alexandre - Abstract:
- Abstract: Partial-thickness tears of the supraspinatus tendon frequently occur at its insertion on the greater tubercule of the humerus, causing pain and reduced strength and range of motion. The goal of this work was to quantify the loss of loading capacity due to tendon tears at the insertion area. A finite element model of the supraspinatus tendon was developed using in vivo magnetic resonance images data. The tendon was represented by an anisotropic hyperelastic constitutive law identified with experimental measurements. A failure criterion was proposed and calibrated with experimental data. A partial-thickness tear was gradually increased, starting from the deep articular-sided fibres. For different values of tendon tear thickness, the tendon was mechanically loaded up to failure. The numerical model predicted a loss in loading capacity of the tendon as the tear thickness progressed. Tendon failure was more likely when the tendon tear exceeded 20%. The predictions of the model were consistent with experimental studies. Partial-thickness tears below 40% tear are sufficiently stable to persist physiotherapeutic exercises. Above 60% tear surgery should be considered to restore shoulder strength.
- Is Part Of:
- Computer methods in biomechanics and biomedical engineering. Volume 19:Issue 8(2016)
- Journal:
- Computer methods in biomechanics and biomedical engineering
- Issue:
- Volume 19:Issue 8(2016)
- Issue Display:
- Volume 19, Issue 8 (2016)
- Year:
- 2016
- Volume:
- 19
- Issue:
- 8
- Issue Sort Value:
- 2016-0019-0008-0000
- Page Start:
- 875
- Page End:
- 882
- Publication Date:
- 2016-06-10
- Subjects:
- Shoulder -- supraspinatus tendon tear -- loading capacity
Biomechanics -- Data processing -- Periodicals
Biomedical engineering -- Periodicals
Biomechanics -- Periodicals
Biomedical Engineering -- methods -- Periodicals
Computing Methodologies -- Periodicals
612.7 - Journal URLs:
- http://www.tandfonline.com/toc/gcmb20/current ↗
http://www.tandfonline.com/ ↗ - DOI:
- 10.1080/10255842.2015.1075012 ↗
- Languages:
- English
- ISSNs:
- 1025-5842
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.100250
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 140.xml