Quantification of aortic stiffness using magnetic resonance elastography: Measurement reproducibility, pulse wave velocity comparison, changes over cardiac cycle, and relationship with age. Issue 5 (12th June 2015)
- Record Type:
- Journal Article
- Title:
- Quantification of aortic stiffness using magnetic resonance elastography: Measurement reproducibility, pulse wave velocity comparison, changes over cardiac cycle, and relationship with age. Issue 5 (12th June 2015)
- Main Title:
- Quantification of aortic stiffness using magnetic resonance elastography: Measurement reproducibility, pulse wave velocity comparison, changes over cardiac cycle, and relationship with age
- Authors:
- Kenyhercz, William E.
Raterman, Brian
Illapani, Venkata Sita Priyanka
Dowell, Joshua
Mo, Xiaokui
White, Richard D.
Kolipaka, Arunark - Abstract:
- Abstract : Purpose: To assess MR elastography (MRE)‐derived aortic shear stiffness (μMRE ) measurements for: 1) reproducibility, 2) comparison to pulse wave velocity, 3) changes over the cardiac cycle, and 4) relationship with age. Methods: Cardiac‐gated aortic MRE was performed on 20 healthy volunteers (aged 20–73 years). For assessing reproducibility of stiffness measurements, scans were repeated per volunteer. MRE wave images were analyzed to obtain stiffness of the abdominal aorta across the cardiac cycle, and comparisons were made with subject age. Results: Analysis of concordance correlation coefficient between scans 1 and 2 showed that rc = 0.86 (95% confidence interval, 0.77, 0.94) with P < 0.0001. Significantly higher μMRE was observed for all volunteers during end‐systole when compared to end‐diastole ( P < 0.0001). μMRE increased with age; end‐systolic stiffness demonstrated a relatively stronger correlation with age ( r = 0.62, P = 0.003) when compared to end‐diastolic stiffness ( r = 0.51, P = 0.023); and the slopes of end‐systole and end‐diastole were found to be significantly different ( P = 0.011). μ M R E at end‐systole and end‐diastole correlated linearly with pulse wave velocity, with an r = 0.54 ( P = 0.013) and r = 0.58 ( P = 0.008), respectively. Conclusion: The results of this study indicate that MRE‐derived aortic shear stiffness measurements are robust (reproducible and comparable to similar techniques). Mean μMRE was higher duringAbstract : Purpose: To assess MR elastography (MRE)‐derived aortic shear stiffness (μMRE ) measurements for: 1) reproducibility, 2) comparison to pulse wave velocity, 3) changes over the cardiac cycle, and 4) relationship with age. Methods: Cardiac‐gated aortic MRE was performed on 20 healthy volunteers (aged 20–73 years). For assessing reproducibility of stiffness measurements, scans were repeated per volunteer. MRE wave images were analyzed to obtain stiffness of the abdominal aorta across the cardiac cycle, and comparisons were made with subject age. Results: Analysis of concordance correlation coefficient between scans 1 and 2 showed that rc = 0.86 (95% confidence interval, 0.77, 0.94) with P < 0.0001. Significantly higher μMRE was observed for all volunteers during end‐systole when compared to end‐diastole ( P < 0.0001). μMRE increased with age; end‐systolic stiffness demonstrated a relatively stronger correlation with age ( r = 0.62, P = 0.003) when compared to end‐diastolic stiffness ( r = 0.51, P = 0.023); and the slopes of end‐systole and end‐diastole were found to be significantly different ( P = 0.011). μ M R E at end‐systole and end‐diastole correlated linearly with pulse wave velocity, with an r = 0.54 ( P = 0.013) and r = 0.58 ( P = 0.008), respectively. Conclusion: The results of this study indicate that MRE‐derived aortic shear stiffness measurements are robust (reproducible and comparable to similar techniques). Mean μMRE was higher during end‐systole when compared to end‐diastole. μMRE was found to increase with age and showed a stronger correlation with end‐systolic stiffness than with end‐diastolic stiffness. Magn Reson Med 75:1920–1926, 2016. © 2015 Wiley Periodicals, Inc. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 75:Issue 5(2016)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 75:Issue 5(2016)
- Issue Display:
- Volume 75, Issue 5 (2016)
- Year:
- 2016
- Volume:
- 75
- Issue:
- 5
- Issue Sort Value:
- 2016-0075-0005-0000
- Page Start:
- 1920
- Page End:
- 1926
- Publication Date:
- 2015-06-12
- Subjects:
- aortic stiffness -- aortic MRE -- MRE -- MR elastography -- pulse wave velocity
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.25719 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 2405.xml